WH-SDC12H6E5, WH-SDC16H6E5, WH-UD12HE5, WH-UD16HE5 - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic WH-SDC12H6E5 / WH-SDC16H6E5 / WH-UD12HE5 / WH-UD16HE5 Service Manual online

Item 
Unit 
Outdoor Unit 
Refrigeration Charge Less 
m (ft) 
10 (32.8) 
Compressor 
Type  
Hermetic 
Motor 
Motor Type 
 
Brushless (4-poles) 
Rated Output 
kW 
3.00 
Fan 
Type  
Propeller 
Fan 
Material  
PP 
Motor Type 
 
DC (8-poles) 
Input Power 
— 
Output Power 
60 
Fan Speed 
rpm 
Cooling: 600 (Top), 640 (Bottom) 
Heating: 510 (Top), 550 (Bottom) 
Heat Exchanger 
Fin material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 51 × 18 
Size (W × H × L) 
mm 
903.7 × 1295.4 × 38.1 
Power Source (Phase, Voltage, Cycle) 
ø Single 
V 230 
Hz 50 
Input Power 
Condition 
(Ambient/Water)
A35W7 A7W35 A2W35 
kW 
Cooling: 3.56 
Heating: 2.53 
Heating: 3.31 
Maximum Input Power For Heatpump System 
kW 
5.30 
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
1Ø / 24.0 / 5.30k 
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
1Ø / 26.0 / 6.00k 
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
— / — / — 
Starting Current 
16.0 
Running Current 
Condition 
(Ambient/Water)
A35W7 A7W35 A2W35 
Cooling: 16.0 
Heating: 11.7 
Heating: 15.0 
Maximum Current For Heatpump System 
24.0 
Power Factor 
Power factor means total figure of compressor and 
outdoor fan motor. 
Cooling: 97 
Heating: 94 
Heating: 96 
Power Cord 
Number of core 
 
— 
Length m 
(ft) 
— 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 