WH-MXC16G9E8 - Panasonic Air Conditioner Service Manual (repair manual). Page 12

Read Panasonic WH-MXC16G9E8 Service Manual online

12 
10
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 11 is skipped.
YES
11
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is
heating up the water tank.
1 hour
20 minutes ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
12
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 13 to 15 are skipped.
YES
13
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~ Sunday
0:00 ~ 23:50
14
Sterilisation Temperature
To set the temperature of sterilisation.
70 °C
15
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
10 minutes
5 minutes ~
1 hour
16
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 17 is skipped.
NO
17
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
A
YES
YES
YES
A
NO
NO
NO
B
18
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from HEAT to COOL.
15 °C
19
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from COOL to HEAT.
10 °C
20
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than
during construction (refer to information page).
-
40 °C ~ 75 °C
5 °C ~ 25 °C
5 °C ~ 25 °C
1 day ~ 99 days
User
Remote control preparation
Press
.
Press
 or
 to set the current day.
Press
 to confirm.
Repeat steps  and  to set the current time.
Note:
The current day and time need to be set in cases below:
- When the power is turned on for the first time.
A long time has elapsed since the power was turned on the
-
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
Dealer
 Operation/settings to be done only by the authorised dealer/specialist.
User
 Operation/settings to be done by the authorised dealer/specialist or user.
*
1
 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
 Only displayed when COOL mode is unlocked (Means when COOL mode is available).
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other WH-MXC16G9E8 service manuals if exist.