WH-ADC0916H9E8, WH-UD09HE8, WH-UD12HE8, WH-UD16HE8, WH-UX09HE8, WH-UX12HE8, WH-UX16HE8, WH-UQ09HE8, WH-UQ12HE8, WH-UQ16HE8 - Panasonic Air Conditioner Service Manual (repair manual)

wh-adc0916h9e8, wh-ud09he8, wh-ud12he8, wh-ud16he8, wh-ux09he8, wh-ux12he8, wh-ux16he8, wh-uq09he8, wh-uq12he8, wh-uq16he8 service manual
Model
WH-ADC0916H9E8 WH-UD09HE8 WH-UD12HE8 WH-UD16HE8 WH-UX09HE8 WH-UX12HE8 WH-UX16HE8 WH-UQ09HE8 WH-UQ12HE8 WH-UQ16HE8
Pages
127
Size
15.43 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR-TO-WATER HYDROMODULE + TANK
File
wh-adc0916h9e8-wh-ud09he8-wh-ud12he8-wh-ud16he8-wh.pdf
Date

Read Panasonic WH-ADC0916H9E8 / WH-UD09HE8 / WH-UD12HE8 / WH-UD16HE8 / WH-UX09HE8 / WH-UX12HE8 / WH-UX16HE8 / WH-UQ09HE8 / WH-UQ12HE8 / WH-UQ16HE8 Service Manual online

 
Order No: PAPAMY1711064CE 
 
 
Air-to-Water Hydromodule + Tank 
 
 
Indoor Unit
Outdoor Unit
WH-ADC0916H9E8
WH-UD09HE8
WH-UD12HE8
WH-UD16HE8
WH-UX09HE8
WH-UX12HE8
WH-UX16HE8
WH-UQ09HE8
WH-UQ12HE8
WH-UQ16HE8
Destination
Europe
 
  WARNING 
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
 
 
 
 
 
  
PRECAUTION OF LOW TEMPERATURE
 
In order to avoid frostbite, be assured of no refrigerant leakage during the instation or repairing of refrigerant circuit.
 
 
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by
in the Schematic
Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.
!
TABLE OF CONTENTS 
1.
 
Safety Precautions ............................................. 4
 
2.
 
Specifications ..................................................... 6
 
2.1
 
WH-ADC0916H9E8  WH-UQ09HE8 ............. 6
 
2.2
 
WH-ADC0916H9E8  WH-UQ12HE8 ........... 10
 
2.3
 
WH-ADC0916H9E8  WH-UQ16HE8 ........... 14
 
2.4
 
WH-ADC0916H9E8  WH-UX09HE8 ............ 18
 
2.5
 
WH-ADC0916H9E8  WH-UX12HE8 ............ 22
 
2.6
 
WH-ADC0916H9E8  WH-UX16HE8 ............ 26
 
2.7
 
WH-ADC0916H9E8  WH-UD09HE8 ............ 30
 
2.8
 
WH-ADC0916H9E8  WH-UD12HE8 ............ 34
 
2.9
 
WH-ADC0916H9E8  WH-UD16HE8 ............ 38
 
3.
 
Features ............................................................. 42
 
4.
 
Location of Controls and Components .......... 43
 
4.1
 
Indoor Unit ................................................... 43
 
4.2
 
Outdoor Unit ................................................. 61
 
5.
 
Dimensions ....................................................... 62
 
5.1
 
Indoor Unit ................................................... 62
 
5.2
 
Outdoor Unit ................................................. 63
 
6.
 
Refrigeration and Water Cycle Diagram ........ 65
 
6.1
 
WH-ADC0916H9E8   
WH-UX09/12/16HE8    
WH-ADC0916H9E8   
WH-UQ09/12/16HE8 ................................... 65
 
6.2
 
WH-ADC0916H9E8   
WH-UD09/12/16HE8.................................... 65
 
7.
 
Block Diagram .................................................. 66
 
7.1
 
WH-ADC0916H9E8  WH-UQ09HE8   
WH-ADC0916H9E8  WH-UQ12HE8  
WH-ADC0916H9E8  WH-UX09HE8   
WH-ADC0916H9E8  WH-UX12HE8 ............ 66
 
7.2
 
WH-ADC0916H9E8  WH-UQ16HE8   
WH-ADC0916H9E8  WH-UX16HE8 ............ 67
 
7.3
 
WH-ADC0916H9E8  WH-UD09HE8   
WH-ADC0916H9E8  WH-UD12HE8  
WH-ADC0916H9E8  WH-UD16HE8 ............ 68
 
8.
 
Wiring Connection Diagram ............................ 69
 
8.1
 
Indoor Unit ................................................... 69
 
8.2
 
Outdoor Unit ................................................. 70
 
9.
 
Electronic Circuit Diagram .............................. 73
 
9.1
 
Indoor Unit ................................................... 73
 
9.2
 
Outdoor Unit ................................................. 74
 
10.
 
Printed Circuit Board ....................................... 77
 
10.1
 
Indoor Unit ................................................... 77
 
10.2
 
Outdoor Unit ................................................. 79
 
11.
 
Operation and Control ..................................... 83
 
11.1
 
Basic Function ............................................. 83
 
11.2
 
Water Pump ................................................. 94
 
11.3
 
Indoor Unit Safety ........................................ 97
 
11.4
 
Auto Restart Control .................................... 97
 
11.5
 
Indication Panel ........................................... 97
 
11.6
 
Indoor Back-Up Heater Control ................... 98
 
11.7
 
Tank Heater Control ..................................... 99
 
11.8
 
Base Pan Heater Control (Optional) ......... 101
 
11.9
 
Heater Turn ON/OFF priority Control ........ 101
 
11.10
 
Force Heater Mode ................................... 101
 
11.11
 
Powerful Operation ................................... 103
 
11.12
 
Quiet Operation ......................................... 104
 
11.13
 
Sterilization Mode ..................................... 104
 
11.14
 
Outdoor Ambient Thermo OFF Control .... 105
 
11.15
 
Alternative Outdoor Ambient Sensor  
Control ...................................................... 105
 
11.16
 
Force DHW mode ..................................... 105
 
11.17
 
SMART DHW mode .................................. 106
 
11.18
 
Anti Freeze Control ................................... 106
 
11.19
 
Solar Operation (Optional) ........................  107
 
11.20
 
Boiler Bivalent Control .............................. 108
 
11.21
 
External Room Thermostat Control  
(Optional) .................................................. 110
 
11.22
 
Three Ways Valve Control ........................ 111
 
11.23
 
Two Ways Valve Control........................... 112
 
11.24
 
External OFF/ON Control ......................... 112
 
11.25
 
External Compressor Switch  
(Optional PCB) ..........................................  113
 
11.26
 
Heat/Cool Switch (Optional PCB) ............. 114
 
11.27
 
SG Ready Control (Optional PCB) ........... 114
 
11.28
 
Demand Control (Optional PCB) .............. 116
 
11.29
 
Holiday Mode ............................................ 116
 
11.30
 
Dry Concrete ............................................. 117
 
11.31
 
Flow Sensor .............................................. 117
 
12.
 
Protection Control (WH-UQ09HE8,  
WH-UQ12HE8 and WH-UQ16HE8) ................ 118
 
12.1
 
Protection Control for All Operations ........ 118
 
12.2
 
Protection Control for Heating  
Operation .................................................. 120
 
12.3
 
Protection Control for Cooling  
Operation .................................................. 122
 
13.
 
Protection Control (WH-UX09HE8,  
WH-UX12HE8 and WH-UX16HE8) ................ 123
 
13.1
 
Protection Control for All Operations ........ 123
 
13.2
 
Protection Control for Heating  
Operation .................................................. 125
 
13.3
 
Protection Control for Cooling  
Operation .................................................. 127
 
14.
 
Protection Control (WH-UD09HE8,  
WH-UD12HE8 and WH-UD16HE8) ................ 128
 
14.1
 
Protection Control for All Operations ........ 128
 
14.2
 
Protection Control for Heating  
Operation .................................................. 130
 
14.3
 
Protection Control for Cooling  
Operation .................................................. 131
 
15.
 
Servicing Guide ............................................. 132
 
15.1
 
How to take out Front Plate ...................... 132
 
15.2
 
Test Run ................................................... 132
 
15.3
 
Expansion Vessel Pre Pressure  
Checking ...................................................  132
 
15.4
 
Pump Down Procedures ...........................  133
 
15.5
 
How To Adjust Pump Speed ..................... 134
 
15.6
 
How To Unlock Cool Mode ....................... 135
 
15.7
 
EEPROM Factory Default Data Setup 
Procedure .................................................. 136
 
15.8
 
Dry Concrete Setup ................................... 137
 
16.
 
Maintenance Guide ........................................ 139
 
16.1
 
Maintenance for Water Filter Set ............... 141
 
17.
 
Troubleshooting Guide .................................. 143
 
17.1
 
Refrigeration Cycle System ....................... 143
 
17.2
 
Relationship between the Condition of the  
Air-to-Water Hydromodule + Tank and  
Air-to-Water Heatpump Outdoor Units  
and Pressure and Electric Current ............ 144
 
17.3
 
Breakdown Self Diagnosis Function .......... 145
 
17.4
 
Error Codes Table ..................................... 147
 
17.5
 
Self-diagnosis Method ............................... 149
 
18.
 
Disassembly and Assembly Instructions .... 197
 
18.1
 
To Remove Front Plate and Top Plate ...... 197
 
18.2
 
To Remove Pressure Gauge ..................... 198
 
18.3
 
To Remove Remote Control ...................... 198
 
18.4
 
To Remove RCCB ..................................... 199
 
18.5
 
To Remove Electronic Controller ............... 199
 
18.6
 
To Remove Flow Switch and Air Purge  
Valve .......................................................... 200
 
18.7
 
To Remove Water Pump ........................... 200
 
18.8
 
To Remove Bottle Complete ..................... 201
 
18.9
 
To Remove Water Filter ............................ 201
 
19.
 
Technical Data ................................................ 202
 
19.1
 
Operation Characteristics .......................... 202
 
19.2
 
Heating Capacity Table ............................. 246
 
19.3
 
Cooling Capacity Table ............................. 249
 
20.
 
Exploded View and Replacement Parts  
List ................................................................... 251
 
20.1
 
Indoor Unit ................................................. 251
 
20.2
 
Outdoor Unit .............................................. 254
 
1. Safety Precautions 
  Read the following “SAFETY PRECAUTIONS” carefully before installation of Air-To-Water Hydromodule + Tank 
(here after referred to as “Tank Unit”). 
  Electrical works and water installation works must be done by licensed electrician and licensed water system 
installer respectively. Be sure to use the correct rating and main circuit for the model to be installed. 
  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. 
Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the 
seriousness is classified by the following indications. 
  Please leave this installation manual with the unit after installation. 
 
 WARNING 
This indication shows the possibility of causing death or serious injury. 
 CAUTION 
This indication shows the possibility of causing injury or damage to properties only. 
 
  The items to be followed are classified by the symbols: 
 
 
Symbol with white background denotes item that is PROHIBITED from doing. 
 
Symbol with dark background denotes item that must be carried out. 
 
  Carry out test run to confirm that no abnormality occurs after the installation. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
  If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice 
and information. 
 
 WARNING 
1. 
Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with 
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 
 
2.  Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen. 
 
3.  Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. 
 
4.  Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction. 
 
5. 
Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or 
fire. 
 
6.  Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc. 
 
7.  Do not use the hot water produced by the Tank Unit for drinking or food preparation. It may cause illness to the user. 
 
8. 
Do not place containers with liquids on top of the Tank Unit. It may cause Tank Unit damage and/or fire could occurs if they leak or 
spill onto the Tank Unit. 
 
9. 
Do not use joint cable for Tank Unit / Outdoor Unit connection cable. Use specified Tank Unit / Outdoor Unit connection cable, refer 
to instruction CONNECT THE CABLE TO THE TANK UNIT and connect tightly for Tank Unit / Outdoor Unit connection. Clamp the 
cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the 
connection. 
 
10. 
For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be 
used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
11. 
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building 
regulation codes. 
12.  Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 
13. 
This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause 
abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A refrigerant. 
Thickness for copper pipes used with R410A must be 0.8 mm or more. 
It is desirable that the amount of residual oil is less than 40 mg/10 m. 
14. 
When install or relocate Tank Unit, do not let any substance other than the specified refrigerant, eg. air etc mix into refrigerant cycle 
(piping). Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc. 
15.  Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
16. 
Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly 
done, the set will drop and cause injury. 
17. 
This equipment is strongly recommended to be installed with Residual Current Device (RCD) on-site according to the respective national 
wiring rules or country–specific safety measures in terms of residual current. 
Page of 127
Display

Download Panasonic WH-ADC0916H9E8 / WH-UD09HE8 / WH-UD12HE8 / WH-UD16HE8 / WH-UX09HE8 / WH-UX12HE8 / WH-UX16HE8 / WH-UQ09HE8 / WH-UQ12HE8 / WH-UQ16HE8 Service Manual (Repair Manual)

Here you can read online and download Panasonic WH-ADC0916H9E8 / WH-UD09HE8 / WH-UD12HE8 / WH-UD16HE8 / WH-UX09HE8 / WH-UX12HE8 / WH-UX16HE8 / WH-UQ09HE8 / WH-UQ12HE8 / WH-UQ16HE8 Service Manual in PDF. WH-ADC0916H9E8 / WH-UD09HE8 / WH-UD12HE8 / WH-UD16HE8 / WH-UX09HE8 / WH-UX12HE8 / WH-UX16HE8 / WH-UQ09HE8 / WH-UQ12HE8 / WH-UQ16HE8 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic WH-ADC0916H9E8 / WH-UD09HE8 / WH-UD12HE8 / WH-UD16HE8 / WH-UX09HE8 / WH-UX12HE8 / WH-UX16HE8 / WH-UQ09HE8 / WH-UQ12HE8 / WH-UQ16HE8 Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.