1-1.  Unit Specifications
PE2
5. Ducted Type S-50PN1E5B / U-50PE2E5A
INDOOR
MODEL
S-50PN1E5B
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-50PE2E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253  /  EN14511  /  EN14825  /  EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
5.0
5.0
5.0
-
-
-
1.5 
5.6
BTU/h
17100
17100
17100
-
-
-
5100
19100
Current
A
0.54
0.55
0.56
7.00
6.65
6.35
-
-
Input power
W
115
120
125
1.445k
1.440k
1.435k
-
-
TOTAL W
-
1.560k
1.560k
1.560k
340
1.890k
Annual consumption
TOTAL kWh *
4
-
-
780
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.21
3.21/A
3.21
4.41
2.96
Erp
*
6
Pdesign
kW
-
-
-
-
5.0
-
-
-
SEER
(W/W)
-
-
-
-
4.6
-
-
-
Annual consumption
kWh
-
-
-
-
380 
-
-
-
Class
-
-
-
-
B
-
-
-
Power factor
%
-
-
-
94 
94 
94 
-
-
Noise indoor
dB-A (H/M/L)
36/34/30
-
-
-
Power Level dB
58/56/52
-
-
-
Noise outdoor
dB-A  (H/L)
-
46/-
-
-
Power Level dB
-
65/-
-
-
H
E
A
T
I
N
G
Capacity
kW
5.6
5.6
5.6
-
-
-
1.5
6.5
BTU/h
19100
19100
19100
-
-
-
5100
22200
Current
A
0.54
0.55
0.56
7.45
7.10
6.75
-
-
Input power
W
115
120
125
1.520k
1.515k
1.510k
-
-
TOTAL W
-
1.635k
1.635k
1.635k
290
1.860k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.43
3.43/B
3.43
5.17
3.49
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
3.8
-
-
-
Tbivalent
°C
-
-
-
-
-10 
-
-
-
SCOP
(W/W)
-
-
-
-
3.8
-
-
-
Annual consumption
kWh
-
-
-
-
1398 
-
-
-
elbu(-10°C)
kW
-
-
-
-
0.00
-
-
-
Class
-
-
-
-
A
-
-
-
Power factor
%
-
-
-
93 
93  
93  
-
-
Noise indoor
dB-A (H/M/L)
36/34/30
-
-
-
Power Level dB
58/56/52
-
-
-
Noise outdoor
dB-A (H/L)
-
48/-
-
-
Power Level dB
-
68/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A)  /  Max Input power(W)
0.76/165
0.79/180
0.80/190
12.0/2.460k
12.0/2.570k
12.0/2.680k
-
Starting current(A)/Comp output(W)
-
-
-
7.45/1.5k
7.10/1.5k
6.75/1.5k
-
Network Impedance(ΩMAX.)
-
-
Fan motor output (Indoor/Outdoor) W
85
60
-
Moisture removal volume
L/h(Pt/h)
2.8
(5.9)
-
-
External static pressure
Pa
25 (MAX80)
-
-
Indoor  
Air flow 
Cooling
m³/min (ft³/min)
16.0/13.0/11.0 (565/459/388)
-
-
-
Heating
m³/min (ft³/min)
16.0/13.0/11.0 (565/459/388)
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
38.0
(1342)
-
-
Heating
m³/min (ft³/min)
-
41.0
(1448)
-
-
Refrigerant type  /  amount g(oz)
-
R410A
1.40k
(49.4)
-
  Product dimension
Height mm(inch)
250 (9-27/32)
619 (24-3/8)
-
Width
mm(inch)
780 [+100] (30-45/64 [+3-15/16])
799 (31-29/64)
-
Depth
mm(inch)
650 (25-19/32)
299 (11-49/64)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
338 (13-5/16)
688
-
Width
mm(inch)
991 (39-1/64)
931
-
Depth
mm(inch)
761 (29-61/64)
422
-
Weight
(NET)
kg(lb)
29 (64)
39 (86)
-
(GROSS)  kg(lb)
34 (75)
44 (97)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit  (actually)
5 (6) 
5 (6) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
Max Working Pressure HP/LP Mpa (bar)
4.15/2.70 (41.5/27.0)
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
3 ~ 40m
(9.8 ~ 131.2)
-
Indoor unit & Outdoor unit height difference  m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
20g/m 
(0.215)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
*1 : In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 :  If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall  
 be used.
*3 : Network Impedance shall be applicable for EUROPE and CHINA models. 
*4 : The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 : EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 :  SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data   
 indicates in an attached sheet.