4
2 Specifications
2.1.
Outdoor Unit 
* Specifications are subject to change without notice for further improvement.
Model Name
U-2E15GBE
Indoor Unit Combination
2.2kW + 2.2kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
4.5 (1.50 - 5.0)
Electrical
Data
Running Current
A
5.75
Power Input
kW
1.230 (0.250 - 1.350)
EER W/W
3.66
Noise
Sound Pressure Level
dB
47
Sound Power Level
dB
62
Heating Operation
Capacity
kW
5.4 (1.1 - 7.0)
Electrical
Data
Running Current
A
5.20
Power Input
kW
1.170 (0.210 - 1.670)
COP
W/W
4.62
Noise
Sound Pressure Level
dB
49
Sound Power Level
dB(A)
64
Maximum Current
A
12.0
Starting Current
A
5.75
Circuit Braker Capacity
A
15
Dimension
Height
mm
540
Width
mm
780 (+70)
Depth
mm
289
Net Weight
kg
38
Connection Cable
3+1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 - 20
Maximum Pipe Length (Total Room)
m
30
Refrigerant Pipe Diameter Liquid Side
mm
6.35
Gas Side
mm
9.52
Compressor
Type
Scroll Type
Motor Type
DC Brushless (4-poles)
Rated Output
W
700
Air Circulation
Type
Propeller Fan
Motor Type
DC Brushless (8-poles)
Rated Output
W
40
Fan Speed
High (Cooling / Heating)
RPM
860 / 820
Heat Exchanger 
Type
Plate fin configuration forced draft type
Tube Material 
Copper
Fin Material
Aluminium
Row/Stage
2/20
FPI
19
Air Volume
High
Cooling
(Heating)
33.3 (28.5)
Refrigerant Control Device
Expansion Valve
Refrigerant Oil  
POE (RB-68A)
Refrigerant (R410A)
g
1450