Read Panasonic S-F18DB4E5 / U-B18DBE5 / S-F24DB4E5 / U-B24DBE5 / S-F28DB4E5 / U-B28DBE5 / S-F28DB4E5 / U-B28DBE8 / S-F34DB4E5 / U-B34DBE5 / S-F34DB4E5 / U-B34DBE8 / S-F43DB4E5 / U-B43DBE8 / S-F50DB4E5 / U-B50DBE8 Service Manual online
16
3.7.
S-F43DB4E5 U-B43DBE8
1. Cooling capacities are based on indoor temperature of 27
qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35
qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20
qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6
qC W.B. (42.8qF W.B.)
ELECTRICAL DATA (50 Hz)
Indoor Unit
Outdoor Unit
Main Body
S-F43DB4E5
U-B43DBE8
ITEM / MODEL
Panel
CZ-BT03P
Remote
Control
CZ-RD513C (Wired)
CZ-RL513B (Wireless)
Cooling Capacity
kW
12.5
BTU/h
42,600
Heating Capacity
kW
14.00
BTU/h
47,700
Refrigerant Charge-less
m
30
Standard Air Volume for High
m
3
/min
31
94
cfm
1095
3316
Outside Dimension (H x W x D)
mm
288
u 840 u 840
1170
u 900 u 320
inch
11-5/16
u 33-1/24 u 33-1/24
46-1/16
u 35-7/16 u 12-19/32
Net Weight
kg (lbs)
28.5 (63)
102 (225)
Piping
Connection
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 15.88 (5/8) Flared Type
Liquid
mm (inch)
O.D Ø 9.52 (3/8) Flared Type
Drain
Compressor
Type, Number of Set
-
Hermatic, 1
Starting Method
-
Permanent Split Capacitor
Motor
Type
-
2-pole 1 phase brushless motor
Rated Output
kW
-
3.75
Fan
Type, Number of Set
Turbo fan-1
Propeller fan,2
Motor
Type
8-pole DC motor
6-pole single phase induction motor
Rated Output
kW
0.06
0.07
u 2
Air-heat Exchanger (Row x Stage x FPI)
Louver-fin type (2
u 12 u 21)
Corrugate-fin type (2
u 44 u 20)
Refrigerant Control
-
Expansion Valve
Refrigerant Oil (Charged)
cm
3
-
DAPHNE FV68D (1500)
Refrigerant (Charged) R410A
kg (oz)
-
3.10 (109)
Running
Adjustment
Adjustment
Control Switch
Wireless or Wired Remote Control
-
Room Temperature
Thermostat
-
Noise Level
dB (A)
Cooling: 46/41
56/-
Heating: 46/41
57/-
Power Level
dB
Cooling: 61/56
70/-
Heating: 61/56
71/-
Moisture Removal
L/h (Pt/h)
7.9 (16.6)
EER
W/W
2.72/2.69/2.66
COP
W/W
3.08/3.05/3.02
ITEM / MODEL
Condition by ISO5151
Volts
V
380
400
415
Phase
Three
Three
Three
Power Consumption
kW
Cooling
4.6
4.65
4.7
Heating
4.54
4.59
4.64
Running Current
A
Cooling
7.8
7.9
8
Heating
7.5
7.7
7.9
Starting Current
A
54
57
60
Power Factor
%
Cooling
90
85
82
Heating
92
86
82
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Panasonic
Power source
AC, 3~380V,400V, 415V 50Hz
Click on the first or last page to see other S-F18DB4E5 / U-B18DBE5 / S-F24DB4E5 / U-B24DBE5 / S-F28DB4E5 / U-B28DBE5 / S-F28DB4E5 / U-B28DBE8 / S-F34DB4E5 / U-B34DBE5 / S-F34DB4E5 / U-B34DBE8 / S-F43DB4E5 / U-B43DBE8 / S-F50DB4E5 / U-B50DBE8 service manuals if exist.