13
1. Cooling capacities are based on indoor temperature of 27
° C Dry Bulb (80.6° F Dry Bulb), 19.0° C Wet Bulb (66.2° F Wet Bulb)
and outdoor air temperature of 35
° C Dry Bulb (95° F Dry Bulb), 24° C Wet Bulb (75.2° F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
° C Dry Bulb (68° F Dry Bulb) and outdoor air temperature of 7° C
Dry Bulb (44.6
° F Dry Bulb), 6° C Wet Bulb (42.8° F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
° C, outdoor 2/1° C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
° C, outdoor
-7/-8
° C
5. Specifications are subjected to change without prior notice for further improvement.
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
—
Minimum
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
MODEL
INDOOR
S-XE9JKDW
OUTDOOR
U-XE9JKD