4.2. CW-C72KD
Item
Pressure (MPa)
Temperature (°C)
A
1.86 ~ 2.06
70 ~ 85
B
1.81 ~ 2.01
31 ~ 41
C
0.59 ~ 0.66
8 ~ 14
D
0.54 ~ 0.59
13 ~ 21
Note: Indoor temperature at 27°C (DB), 19°C (WB) and Outdoor at
35°C (DB), 24°C (WB).
4.3. CW-C92KD
Item
Pressure (MPa)
Temperature (°C)
A
1.96 ~ 2.22
71 ~ 89
B
1.91 ~ 2.06
35 ~ 45
C
0.56 ~ 0.63
7 ~ 12
D
0.50 ~ 0.56
6 ~ 14
Note: Indoor temperature at 27°C (DB), 19°C (WB) and Outdoor at
35°C (DB), 24°C (WB).
4 Refrigeration Cycle Diagram
4.1. 
5 Air Conditioner Performance Evaluation
Intake & Discharge Air
Temperature Difference
Current Drain
Determination
Remedy
    • 
• 
• 
• 
8°C and over (14.4°F)
    • 
• 
• 
• 
As specified.
    • 
• 
• 
• 
Nothing wrong.
    • 
• 
• 
• 
None.
    • 
• 
• 
• 
8°C and over (14.4°F)
    • 
• 
• 
• 
Higher than specified.
    • 
• 
• 
• 
Nothing wrong, outdoor
temperature is too high, heat
radiation is not efficient.
    • 
• 
• 
• 
Improve heat radiation.
    • 
• 
• 
• 
Under 8°C (14.4°F)
    • 
• 
• 
• 
Higher than specified.
    • 
• 
• 
• 
Something is preventing heat
radiation.
    • 
• 
• 
• 
Excessive amount of refrigerant.
    • 
• 
• 
• 
Improve heat radiation.
    • 
• 
• 
• 
Under 8°C (14.4°F)
    • 
• 
• 
• 
Lower than specified.
    • 
• 
• 
• 
Leakage of refrigerant or
refrigerant system is blocked.
    • 
• 
• 
• 
Locate repair leak.
    • 
• 
• 
• 
Flush refrigeration cycle.
    • 
• 
• 
• 
Under 8°C (14.4°F)
    • 
• 
• 
• 
Higher than specified by
50%.
    • 
• 
• 
• 
Compressor defect.
    • 
• 
• 
• 
Replace the compressor.
Note: Room air humidity is relatively higher, the temperature difference will be smaller.
6 Troubleshooting Guide
Warning: Disconnect unit from electrical power supply before making any electrical checks.
Trouble
Check
Result
Cause
Remedy
Fan Motor and Compressor
won’t run.
    • 
• 
• 
• 
Supply Voltage
    • 
• 
• 
• 
Fuse Box or Circuit
Breaker.
    • 
• 
• 
• 
Power cord or
Wiring Harness.
    • 
• 
• 
• 
Thermostat Setting.
    • 
• 
• 
• 
Less than 10% by
Rated.
    • 
• 
• 
• 
Open Contacts.
    • 
• 
• 
• 
Pulled loose or
Shorted.
    • 
• 
• 
• 
Higher than room
temp.
    • 
• 
• 
• 
Temporary or Permanent?
    • 
• 
• 
• 
Customer Restarted unit
immediately without waiting
3 minutes.
    • 
• 
• 
• 
Consult ELECTRICIAN, If
permanent.
    • 
• 
• 
• 
Repair Open Circuit.
    • 
• 
• 
• 
WAIT FOR 3 MINUTES.
    • 
• 
• 
• 
Repair or Replace it.
    • 
• 
• 
• 
Set it LOWER.