11.3. Sensible Capacity Chart
     • 
• 
• 
• 
CW-C71YE
230V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.04
1.55
0.71
1.91
1.49
0.76
1.78
1.43
0.81
1.62
1.36
0.88
19.0°C
2.06
0.77
19.5°C
2.24
1.62
0.72
2.10
1.56
0.77
1.95
1.50
0.83
1.77
1.43
0.89
22.0°C
2.45
1.68
0.73
2.28
1.62
0.79
2.13
1.56
0.84
1.93
1.49
0.91
220V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.04
1.55
0.67
1.91
1.49
0.72
1.78
1.43
0.77
1.62
1.36
0.83
19.0°C
2.06
0.73
19.5°C
2.24
1.62
0.68
2.10
1.56
0.73
1.95
1.50
0.78
1.77
1.43
0.85
22.0°C
2.45
1.68
0.69
2.28
1.62
0.75
2.13
1.56
0.80
1.93
1.49
0.86
     • 
• 
• 
• 
CW-C91YE
230V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.63
1.99
0.93
2.46
1.91
0.99
2.28
1.84
1.06
2.08
1.75
1.15
19.0°C
2.65
1.01
19.5°C
2.89
2.09
0.94
2.70
2.00
1.01
2.51
1.93
1.08
2.28
1.84
1.17
22.0°C
3.15
2.16
0.96
2.94
2.08
1.03
2.73
2.01
1.10
2.49
1.91
1.19
220V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.62
1.99
0.86
2.45
1.90
0.92
2.28
1.83
0.99
2.07
1.74
1.06
19.0°C
2.64
0.94
19.5°C
2.87
2.08
0.87
2.69
2.00
0.94
2.50
1.92
1.00
2.27
1.83
1.08
22.0°C
3.13
2.16
0.89
2.93
2.07
0.96
2.72
2.00
1.02
2.48
1.91
1.10
14
CW-C71YE / CW-C91YE
Page of 16
Display