Read Panasonic CU-4E27PBD / CU-5E34PBD Service Manual online
5
2. Specifications
2.1 CU-4E27PBD
Item
Unit OUTDOOR
UNIT
Indoor Unit Combination
2.2kW + 2.2kW + 2.2kW + 7.0kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
8.0 (3.0 ~ 9.2)
BTU/h
27300 (10200 ~ 31400)
Electrical
Data
Running Current
A
9.4
Power Input
kW
1.98 (0.53 ~ 2.87)
EER
W/W
4.04 (5.66 ~ 3.21)
Noise
Sound Pressure Level
dB-A (H/L)
51 / -
Sound Power Level
dB (H/L)
67 / -
Heating Operation
Capacity
kW
9.4 (4.2 ~ 10.6)
BTU/h
32100 (14300 ~ 36100)
Electrical
Data
Running Current
A
9.8
Power Input
kW
2.08 (0.70 ~ 3.06)
COP
W/W
4.52 (6.00 ~ 3.46)
Noise
Sound Pressure Level
dB-A (H/L)
52 / -
Sound Power Level
dB (H/L)
68 / -
Maximum Current
A
19.0
Starting Current
A
9.8
Circuit Breaker Capacity
A
20
Dimension
Height mm
999
Width mm
940
Depth mm
340
Net Weight
kg
80
Connection Cable
3 + 1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 ~ 25
Maximum Pipe Length (Total Room)
m
70
Refrigerant Pipe Diameter
Liquid Side
mm (inch)
6.35 (1/4)
Gas Side
mm (inch)
9.52 (3/8) (E21 & E24:12.7 (1/2))
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4-poles)
Rated Output
W
1.70k
Air Circulation
Type
Propeller
Fan
Motor Type
DC Motor (8-poles)
Rated Output
W
90
Fan Speed
High (Cooling / Heating)
RPM
550 / 600
Heat Exchanger
Type
Plate fin configuration forced draft type
Tube Material
Copper
Fin Material
Aluminum (Pre Coat)
Row / Stage
2 / 46
FPI
19
Air Volume
High (Cooling / Heating)
m
3
/min
50.4 / 55.6
Refrigerant Control Device
Expansion Valve
Refrigerant Oil
FV50S
Refrigerant (R410A)
g
3.40k
Click on the first or last page to see other CU-4E27PBD / CU-5E34PBD service manuals if exist.