For Automatic operation, the indoor fan will operate at Slo speed for 25 seconds, 30 minutes before the set time 
to detect the intake air temperature to determine the operation mode. The power LED will blink during detection. 
If main power supply is switched off or encounter power failure, timer setting will be cancel. Timer needs to be 
reset 
The ON timer or OFF timer will be cancel by pressing CANCEL button. 
The ON timer or OFF timer will be cancel is ON/OFF operation button is pressed. 
Each timer setting is effective only once.  
If power failure occurs during timer operation, timer will be canceled. Reset timer when power is resumed. 
 
10.10 Random Auto Restart Control 
If there is a power failure during operation, the air conditioner will automatically restart after 2 minutes when the 
power is resumed. 
It will start with previous operation mode and airflow direction. 
If timer is set, timer setting will be cancel. The timer needs to be reset after the power is resumed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 