9. Installation Instruction 
9.1  Select The Best Location  
9.1.1 Indoor Unit 
•  There should not be any heat source or steam near the unit.  
•  There should not be any obstacles blocking the air circulation. 
•  A place where air circulation in the room is good. 
•  A place where drainage can be easily done. 
•  A place where noise prevention is taken into consideration. 
•  Do not install the unit near the door way.  
•  Ensure the spaces indicated by arrows from the wall, ceiling, fence 
or other obstacles. 
•  Recommended installation height for indoor unit shall be at least 
2.5m. 
9.1.2 Outdoor Unit 
•  If an awning is built over the unit to prevent direct sunlight or rain, 
be careful that heat radiation from the condenser is not obstructed. 
•  There should not be any animal or plant which could be affected by 
hot air discharged. 
•  Keep the spaces indicated by arrows from wall, ceiling, fence or 
other obstacles. 
•  Do not place any obstacles which may cause a short circuit of the 
discharged air. 
•  If piping length is over the rated length, additional refrigerant should 
be added as shown in the table below: 
 
 
 
Example: For YW12MKD 
If the unit is installed at a 10m distance, the quantity of additional refrigerant  
should be 50 g.…… (10-7) m x 20g/m = 60 g 
 
 
 
Piping size
Model 
Gas 
Liqui
Rate
Leng
th 
(m) 
Max 
Elevati
on (m) 
Min 
Piping 
Length 
(m)
Max 
Piping 
Length 
(m) 
Addition
al 
Refriger
ant 
(g/m)
Piping 
Length 
for add. 
Gas (m)
CS/CU-YW7MKD 
3/8” 1/4"
5.0  5.0 
CS/CU-YW9MKD 
3/8” 1/4”
5.0  5.0 
CS/CU-YW12MKD 
3/8” 1/4”
5.0  5.0 3  10  20  7.0 
CS/CU-YW7MKD-1 
3/8” 1/4"
5.0  5.0 
CS/CU-YW9MKD-1 
3/8” 1/4”
5.0  5.0 
CS/CU-YW12MKD-1 
3/8” 1/4”
5.0  5.0 3  10  20  7.0 
9.1.3 Indoor/Outdoor Unit
*This illustration is for explanation 
purposes only. 
 The indoor unit will actually face a 
different way. 
Page of 41