CS-XE9HKD, CS-XE12HKD, CU-XE9HKD, CU-XE12HKD - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-XE9HKD / CS-XE12HKD / CU-XE9HKD / CU-XE12HKD Service Manual online

6
1. Cooling capacities are based on indoor temperature of 27
qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35
qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20
qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6
qC W.B. (42.8qF W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASG20K1
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
47
Output Power
W
30
25
Fan Speed
QLo (Cool/Heat)
rpm
 720 / 890
Lo (Cool/Heat)
rpm
 830 / 940
Me (Cool/Heat)
rpm
1070 / 1180
Hi (Cool/Heat)
rpm
1310 / 1420
745 - 770 / —
SHi (Cool/Heat)
rpm
1390 / 1490
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 19
2 x 24 x 17
Size (W x H x L)
mm
610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
W
Cooling; 590 (175 ~ 750)
Heating; 835 (165 ~ 1340)
Starting Current
A
4.1
Running Current
A
Cooling; 3.0 - 2.8
Heating; 4.1 - 3.9
Power Factor
%
Cooling; 89 - 92
Heating; 93 - 93
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
5.9
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Page of 69
Display