8
Note:
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
2 / 24
FPI
20
17
Size (W 
u H u L)
mm
610 
u 315 u 25.4
718.4 
u 504 u 36.4
           689.8
Refrigerant Control Device
Exp. Valve
Refrigerations Oil
(cm
3
)
RB68A (400)
Refrigerant (R410A)
g (oz)
970 (34.2)
Thermostat
Electronic Control
Protection Device
Electronic Control
Capillary Tube
Length
mm
Flow Rate
I/min
Inner Diameter
mm
Air Filter
Material
PET
Style
Compressor Capacitor
PF, VAC
Fan Motor Capacitor
PF, VAC
Unit
CS-XE12EKE
CU-XE12EKE
Page of 79
Display