10.2.5. CONNECT THE CABLE TO THE
INDOOR UNIT
 1. The inside and outside connecting cable can be connected
without removing the front grille.
 2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 4 (XE9CK,
XE12CK) × 1.5 mm
2
flexible cord, type designation 245 IEC
57 or heavier cord.
     • 
• 
• 
• Ensure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
     • 
• 
• 
• Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
     • 
• 
• 
• Secure the cable onto the control board with the holder
(clamper).
INSTALLATION OF AIR PURIFYING FILTER
 1. Open the front panel.
 2. Remove the air filters.
 3. Put air purifying filter into place as shown in illustration
below.