CS-XE9CKE, CU-XE9CKE, CS-XE12CKE, CU-XE12CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE Service Manual online

3 Product Specifications
Unit
CS-XE9CKE
CU-XE9CKE
Cooling Capacity
kW
kcal/h
BTU/h
2.6 (0.60 - 3.00)
2,240 (520 - 2,580)
8,870 (2,050 - 10,200)
Heating Capacity
kW
kcal/h
BTU/h
3.6 (0.60 - 5.00)
3,100 (520 - 4,300)
12,300 (2,050 - 17,100)
Moisture Removal
l/h
Pint/h
1.6
(3.4)
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 6.5 (231)
Heating; 7.1 (249)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 8.1 (286)
Heating; 8.8 (312)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 9.9 (350)
Cooling; 30.0 (1,060)
Heating; 10.6 (370)
dB (A)
Cooling; High 39, Low 26
Cooling; 46
Heating; High 40, Low 27
Heating; 47
Noise Level
Power level dB
Cooling; High 50
Cooling; High 59
Heating; High 51
Heating; High 60
Electrical Data
Input
W
Cooling; 700 (115 - 880)
Heating; 900 (110 - 1,400)
Running Current
A
Cooling; 3.3
Heating; 4.0
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.71(3.20), 12.7
COP
W/W (kcal/hw), BTU/hw
Heating; 4.00 (3.44), 13.7
Starting Current
A
4.00
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
6
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Page of 110
Display

Click on the first or last page to see other CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE service manuals if exist.