Read Panasonic CS-XE18HKD / CS-XE24HKD / CU-XE18HKD / CU-XE24HKD Service Manual online
6
1. Cooling capacities are based on indoor temperature of 27
qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35
qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20
qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6
qC W.B. (42.8qF W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 19
2 x 34 x 18
Size (W x H x L)
mm
810 x 315 x 25.4
36.4 x 714 x 851.9
823.2
Air Filter
Material
Polypropelene
—
Type
One-Touch
—
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V
220
230
Hz
50
50
Input Power
W
Cooling; 1.65k (215 ~ 2.05k)
Cooling; 1.65k (215 ~ 2.05k)
Heating; 1.79k (245 ~ 2.65k)
Heating; 1.79k (245 ~ 2.65k)
Starting Current
A
8.3
8.3
Running Current
A
Cooling; 7.7
Cooling; 7.5
Heating; 8.3
Heating; 8.1
Maximum current
A
11.9
11.9
Power Factor
%
Cooling; 97
Cooling; 96
Heating; 98
Heating; 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
—
—
Length
m
—
—
Thermostat
Protection Device
Annual Consumption
kWh
825
825
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Click on the first or last page to see other CS-XE18HKD / CS-XE24HKD / CU-XE18HKD / CU-XE24HKD service manuals if exist.