Read Panasonic CS-XC9CKT / CU-XC9CKT / CS-XC12CKT / CU-XC12CKT Service Manual online
1. Remove the screw and Particular Piece.
2. Take out the Oxygen tube.
3. Slide out the Filter - Oxygen Generator.
4. Take out the Discharge and Inlet Oxygen tube. (Make sure
connect back to Original place.)
5. Release the connectors.
6. Remove the 3 screws Control Board.
7. Remove th ground screw.
8. Remove the 4 screws at the bottom vacuum pump and take
out the vacuum pump.
12.2.2. Filter - Oxygen Generator and Vacuum Pump Removal Procedures
61
CS-XC9CKT CU-XC9CKT / CS-XC12CKT CU-XC12CKT