Indoor Unit
Ionizer Control
Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
_ Cooling : Fan rotates at Hi, Me and SLo
speed. Deodorizing control is
available.
_ Soft Dry : Fan rotates at Lo- speed.
Deodorizing control is
available.
Automatic air swing and manual adjusted
by remote control for vertical airflow.
Manually adjusted by hand for horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
Press continuously for 5s or < 10s  to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
Press continuously for 10s or < 15s  to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green)......... Lights up in operation,
blinks in Automatic
Operation Mode judging.
Operation Mode
Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Oxygen Operation
To supply oxygen enrich air.
Time Delay Safety Control
Restarting is inhibited for appro. 3
minutes.
Starting Current Control
Quiet Operation
To provide quiet operation.
7 Minutes Time Save Control
Cooling Operation only.
Indoor fan motor is delayed for 1.6 seconds
when indoor, outdoor fan motor and 
compressor starts simultaneously.
Random Auto Restart Control
Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Press continuously for 15s and above to
testify oxygen operation. "Beep, beep, beep"
sound will be heard at the 15th second.
QUIET
 
(Orange)......... Lights up in Quiet Mode
Operation.
TIMER
 
(Orange)......... Lights up in Timer
Setting.
(Green)
...
....
Lights up in Oxygen
Mode Operation.
 
ION 
(Green) ............ Lights up in Ionizer
Mode Operation.
4
CS-XC9CKT CU-XC9CKT / CS-XC12CKT CU-XC12CKT
Page of 78
Display