Unit
CS-W24CKE
CU-W24CKE
Power Source
Phase, Voltage, Cycle
Single, 230, 50 Hz
Cooling Capacity
kW (BTU/h)
7.03 (24,000)
Heating Capacity
kW (BTU/h)
7.72 (26,300)
Moisture Removal
l/h (Pint/h)
4.0 (8.5)
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 14.4 (510)
Heating; 15.6 (550)
27.4 (970)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 16.4 (580)
Heating; 16.4 (580)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 17.5 (620)
Heating; 18.1 (640)
47.2 (1,670)
Indoor Air (SHi)
m
3
/min (cfm)
Cooling; 18.1 (640)
Heating; 18.1 (640)
Noise Level
dB (A)
Cooling; High 47, Low 41
Heating; High 46, Low 41
Cooling; High 60
Heating; High 61
Power level dB
Cooling; 59
Heating; 57
Coolling; 74
Heating; 74
Electrical Data
Input Power
kW
Cooling; 2.78
Heating; 2.69
Running Current
A
Cooling; 13.1
Heating; 12.9
EER
W/W (BTU/hW)
Cooling; 2.53 (8.63)
COP
W/W (BTU/hW)
Heating; 2.87 (9.79)
Starting Current
A
65.0
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 5/8”
L ; Half Union 1/4”
G ; 3-way valve 5/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G ; (gas side) 5/8”
L ; (liquid side) 1/4”
G ; (gas side) 5/8”
L ; (liquid side) 1/4”
Drain
Hose
Inner diameter
mm
12
Length
mm
650
Power Cord
Length
m
1.9
Number of core-wire
3 (2.5 mm
2
)
Dimensions
Height
inch (mm)
10 - 13/16 (275)
26 - 31/32 (685)
Width
inch (mm)
39 - 9/32 (998)
31 - 1/2 (800)
Depth
inch (mm)
8 - 9/32 (210)
11 - 13/16 (300)
Net Weight
lb (kg)
24 (11.0)
135 (61.0)
Compressor
Type
Rotary (1 cylinder) rolling piston
type
Motor
Type
Induction (2-poles)
Rated
Output
kW
2.2
8
CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE