CS-W18CKE, CU-W18CKE, CS-W24CKE, CU-W24CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 18

Read Panasonic CS-W18CKE / CU-W18CKE / CS-W24CKE / CU-W24CKE Service Manual online

Cooling Operation Time Diagram
Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
     • 
• 
• 
• Purpose of this operation is to provide quite cooling operation compare to normal operation.
     • 
• 
• 
• When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
3 dB, against the present sound level operation.
     • 
• 
• 
• Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
     • 
• 
• 
• Dew formation become severe at Quiet Lo cool, therefore:
i) For Transistor Motor
Quiet Lo Cool is operated only 1h 30 minute (1h QLo, 30 min QLo+100). After that, it goes back to QLo+180 rpm. (However
quiet LED remains on).
ii) For Induction Motor
Quiet Lo Cool is operated only 1h 30 minute (1h QLo, 30 min QLo+80). After that, it goes back to QLo+170 rpm. (However quiet
LED remains on).
18
CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE
Page of 87
Display