TIMER TABLE
Test Mode
Name
Time
(When test point
Remarks
Short-circuited)
Sleep Mode Waiting
1 hr.
6 sec.
Sleep Mode Operation
8 hrs.
48 sec.
Real Timer
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
Time Delay Safety Control
2 min. 58 sec.
0 sec.
Forced Operation
60 sec.
0 sec.
Time Save Control
7 min.
42 sec.
Anti-Freezing
4 min.
0 sec.
Mode Judgement
20 sec.
0 sec.
Soft
OFF
6 min.
36 sec.
ON
10 min.
60 sec.
Soft Dry: 10 min. operation
Deodorizing Control
Cooling
40 sec.
4 sec.
70 sec.
7 sec.
20 sec.
2 sec.
Soft Dry
180 sec.
18 sec.
40 sec.
4 sec.
360 sec.
36 sec.
Comp. Reverse Rotation Detection
5 min.
30 sec.
Comp. ON 5 min. and above
2 min
0 sec.
Comp./ Fan Motor Delay Timer
1.6 sec.
0 sec.
Intake Air Anti-Freezing Prevention
16 min.
96 sec.
Powerful Mode
15 min.
15 sec
Random FM Timer (Economy Mode)
5 sec.
5 sec.
Random Auto Restart Control
0 ~ 150 sec.
0 sec.