Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Louver Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 14
1 × 18
FPI
18
17
Size (W × H × L)
mm
614 × 294 × 25.4
856 × 457.2 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
RB68A
(350)
Refrigerant (R410A)
g (oz)
870 (30.7)
Thermostat
Electronic Control
Protection Device
2 Stage Overload Protector
Capillary Tube
Length
mm
590
Flow Rate
l/min
8.2
Inner Diameter
mm
1.3
Air Filter
Material
Style
(c.c)
P.P.
Honeycomb
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
30 µF, 370VAC
Fan Motor Capacitor
µF, VAC
1.5 µF, 400VAC
1.2 µF, 400VAC
  • 
Specifications are subject to change without notice for further improvement.