110 
18.4.19    F11 (4-way Valve Switching Failure) 
Malfunction Decision Conditions 
  When indoor heat exchanger is cold during heating (except deice) or when indoor heat exchanger is hot during 
cooling and compressor operating, the 4-way valve is detected as malfunction. 
 
Malfunction Caused 
  Indoor heat exchanger (pipe) thermistor 
  4-way valve malfunction 
 
Troubleshooting 
 
 
 
* Check gas side pipe – for hot gas flow in cooling mode 
 
 
 
 
 
 
 
Page of 127