CS-TZ50TKEW, CU-TZ50TKE - Panasonic Air Conditioner Service Manual (repair manual). Page 9

Read Panasonic CS-TZ50TKEW / CU-TZ50TKE Service Manual online

3. Specifications 
Model 
Indoor CS-TZ50TKEW 
Outdoor CU-TZ50TKE 
Performance Test Condition 
EUROVENT 
Power Supply 
Phase, Hz 
Single, 50 
V 230 
 Min. 
Mid. 
Max. 
Cooling 
Capacity 
kW 
0.98 5.00 5.60 
BTU/h 3340 
17100 
19100 
Kcal/h 840 
4300 
4820 
Running Current 
– 
6.50 
– 
Input Power 
285 
1.47k 
1.73k 
Annual 
Consumption 
kWh 
– 735 – 
EER 
W/W 
3.44 3.40 3.24 
BTU/hW 
11.72 11.63 11.04 
Kcal/hW 
2.95 2.93 2.79 
ErP 
Pdesign kW 
5.0 
SEER (W/W) 
6.8 
Annual 
Consumption 
kWh 257 
Class  
A++ 
Power 
Factor 
– 98 – 
Indoor Noise (H / L / QLo) 
dB-A 
44 / 37 / 34 
Power Level dB 
60 / 53 / 50 
Outdoor Noise (H / L) 
dB-A 
48 / – 
Power Level dB 
63 / – 
Heating
 
Capacity 
kW 
0.98 5.80 7.80 
BTU/h 3340 
19800 
26600 
Kcal/h 840 
4990 
6710 
Running Current 
– 
6.90 
– 
Input Power 
340 
1.54k 
2.30k 
COP 
W/W 
2.88 3.77 3.39 
BTU/hW 9.82 
12.86 
11.57 
Kcal/hW 
2.47 3.24 2.92 
ErP 
Pdesign kW 
4.0 
Tbivalent °C 
-10 
SCOP (W/W) 
4.3 
Annual 
Consumption 
kWh 1302 
Class  
A+ 
Power 
Factor 
– 97 – 
Indoor Noise (H / L / QLo) 
dB-A 
44 / 37 / 34 
Power Level dB 
60 / 53 / 50 
Outdoor Noise (H / L) 
dB-A 
49 / – 
Power Level dB 
64 / – 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
5.65 / 2.04k / 2.77 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
4.79 / 1.95k / 2.46 
Max Current (A) / Max Input Power (W) 
10.5 / 2.30k 
Starting Current (A) 
6.90 
 
Page of 127
Display