Read Panasonic CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 Service Manual online
124
20.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 230V
Voltage: 230V
20.2.1 CS-TZ20TKEW-1
CU-TZ20TKE-1
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 1691 750 2006 845 2611 879 2597 651 2765 648
20 1694 710 2140 840 2610 900 2700 650 2876 648
16 1596 672 2273 804 2706 857 2969 649 3048 646
20.2.2 CS-TZ25TKEW-1
CU-TZ25TKE-1
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 1964 886 2531 1037 2972 967 3174 791 3379 787
20 1967 838 2700 1030 2970 990 3300 790 3515 787
16 1854 793 2868 986 3079 942 3629 789 3726 786
20.2.3 CS-TZ35TKEW-1
CU-TZ35TKE-1
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 2715 1186 3034 1318 3630 1192 3661 992 3897 986
20 2719 1122 3300 1310 3700 1220 4000 990 4054 986
16 2562 1062 3437 1254 3761 1161 4185 989 4297 984
TC - Total Heating Capacity (W)
IP - Input Power (W)