CS-TZ20TKEW-1, CS-TZ25TKEW-1, CS-TZ35TKEW-1, CU-TZ20TKE-1, CU-TZ25TKE-1, CU-TZ35TKE-1 - Panasonic Air Conditioner Service Manual (repair manual). Page 117

Read Panasonic CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 Service Manual online

117 
18.4.28    F99 (DC Peak Detection) 
Malfunction Decision Conditions 
During startup and operation of cooling and heating, when inverter DC peak data is received by the outdoor internal 
DC Peak sensing circuitry. 
 
Malfunction Caused 
  DC current peak due to compressor failure. 
  DC current peak due to defective power transistor(s). 
  DC current peak due to defective outdoor unit PCB. 
  DC current peak due to short circuit. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 service manuals if exist.