CS-TE9HKE, CS-TE12HKE, CU-TE9HKE, CU-TE12HKE - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic CS-TE9HKE / CS-TE12HKE / CU-TE9HKE / CU-TE12HKE Service Manual online

5
1. Cooling capacities are based on indoor temperature of 27
qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35
qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20
qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6
qC W.B. (42.8qF W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASG20K1 or ASG32K1
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
30
Output Power
W
30
25
Fan Speed
Lo (Cool/Heat)
rpm
 910 / 980
Me (Cool/Heat)
rpm
1130 / 1240
Hi (Cool/Heat)
rpm
1370 / 1510
770 / -
SHi (Cool/Heat)
rpm
1430 / 1460
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2.1 x 11.4 x 23
2 x 24 x 17
Size (W x H x L)
mm
640 x 304 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 570 (175 ~ 730)
Heating; 870 (165 ~ 1.15k)
Starting Current
A
4.0
Running Current
A
Cooling; 2.6
Heating; 4.0
Maximum current
A
5.3
Power Factor
%
Cooling; 95
Heating; 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.0mm)
Length
m (ft)
1.5 (5)
Thermostat
Electrical
Protection Device
Annual Consumption
kWh
285
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Page of 61
Display