CS-SA9CKP, CUSA9CKP5, CS-SA12CKP, CUSA12CKP5 - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-SA9CKP / CUSA9CKP5 / CS-SA12CKP / CUSA12CKP5 Service Manual online

Unit
CS-SA12CKP
CU-SA12CKP5
Air Circulation
Type
Cross-flow Fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (6 pole)
Input
W
58.6
Rate Output
W
13
20
Fan Speed
Low
rpm
980
Medium
rpm
1090
High
rpm
1200
750
Heat Exchanger
Discription
Evaporator
Condenser
Tube Material
copper
copper
Fin Type
slot type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 15
1 × 20
FPI
18
18
Dimensions
mm
610 × 315 × 25.4
706.2 × 482.6 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(350)
Refrigerant (R-22)
g
940
Thermostat
Electronic Control
Protection Device
Overload Protector
Capillary
Length
mm
Cooling: 470, Heating: 1160
Circulation
L/min
Cooling: 13.4, Heating: 4.5
Inner dia
mm
Cooling: 1.5, Heating: 1.2
Air Filter
P.P Honeycomb
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
30µF, 370V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.8µF, 400V
     • 
• 
• 
• Specifications are subject to change without notice for further improvement
     • 
• 
• 
• The amount of refrigerant (60g) for air purging not included
8
CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
Page of 62
Display

Click on the first or last page to see other CS-SA9CKP / CUSA9CKP5 / CS-SA12CKP / CUSA12CKP5 service manuals if exist.