Read Panasonic CS-PC9CKH / CU-PC9CKH / CS-SC9CKH / CU-PC9CKH / CS-PC12CKH / CU-PC12CKH / CS-SC12CKH / CU-PC12CKH Service Manual online
Indoor Unit
CS-PC9CKH
CS-PC12CKH
CS-PC12CKH
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
• Automatic Fan Speed Mode
–
Cooling : Fan rotates at Hi, Me and
SLo speed.
–
Soft Dry: Fan rotates at Lo- speed.
• Automatic air swing selected by remote
control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot
be used.)
(Used when the remote control cannot
be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
Operation Mode
judging.
•
TIMER
(Orange) ........ Lights up in TIMER
Operation.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Time Delay Safety Control
• Restarting is inhibited for appro. 3
minutes.
Starting Current Control
7 Minutes Time Save Control
• Cooling Operation only.
• Fan motor is delayed for 1.6 seconds
when compressor starts simultaneously.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)