Read Panasonic CS-MZ20UD3EA Service Manual online
24
12. Installation
Instruction
■ Required Materials
Read the catalog and other technical materials
and prepare the required materials.
Applicable piping kit
Applicable piping kit
Piping size
Gas Liquid
CZ-3F5, 7BP
9.52 mm (3/8")
6.35 mm (1/4")
CZ-4F5, 7, 10BP
12.7 mm (1/2")
6.35 mm (1/4")
CZ-52F5, 7, 10BP
15.88 mm (5/8")
6.35 mm (1/4")
Pipe Size Reducer (CZ-MA1P) and Expander
(CZ-MA2P) for Outdoor Multi Connection
CS-Z50******, CS-Z60******.
CS-Z50******, CS-Z60******.
Please refer to “Connect the piping”.
■ Other Items to be Prepared (Locally Purchased)
Product name
Remarks
Rigid PVC pipe
VP20 (outer diameter ø26); also
sockets, elbows and other parts as
necessary
sockets, elbows and other parts as
necessary
Adhesive
PVC adhesive
Insulation
For refrigerant piping insulation :
foamed polyethylene with a thickness of
8 mm or more.
For drain piping insulation : foamed
polyethylene with a thickness of 10 mm
or more.
foamed polyethylene with a thickness of
8 mm or more.
For drain piping insulation : foamed
polyethylene with a thickness of 10 mm
or more.
Indoor/outdoor
connecting cable
connecting cable
4 x 1.5 mm
2
flexible cord, designation
type 60245 IEC 57 (H05RN-F)
Hanging bolt related
parts
parts
Hanging bolts (M10) (4) and nuts (12),
(when hanging the indoor unit)
(when hanging the indoor unit)
Table A
Model Capacity
Indoor A
min
(m
2
)
2.2m for ducted
2.5m for ducted
Z25****** 1.0HP 0.64 0.50
Z35****** 1.5HP 0.71 0.55
Z50****** 2.0HP 1.37 1.06
Z60****** 2.25HP 1.37 1.06
* Table “A” only applicable for single split connection.
* In case of connection to outdoor multi inverter, refer
* In case of connection to outdoor multi inverter, refer
to installation manual at outdoor unit.
A
min
= (M / (2.5 × (LFL)
(5/4)
× h
0
))
2
A
min
= Required minimum room area, in m
2
M
= Refrigerant charge amount in appliance, in kg
LFL = Lower flammable limit (0.306 kg/m
3
)
h
0
= Installation height of the appliance: (2.2m for ducted is standard reference installed height)
(2.5m for ducted is minimum installed height given by manufacturer)
Attaching the remote controller to the wall
Screws
3
or
screws
4
Remote controller
cable
cable
2
Remote controller
1
Details refer to
3. INSTALLING
THE INDOOR
UNIT (Remote
Control
Installation)
3. INSTALLING
THE INDOOR
UNIT (Remote
Control
Installation)
Insulation of piping connections
• Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
secure with vinyl tape.
Vinyl tape
Sleeve ( )
Bushing-Sleeve ( )
Putty (Gum Type Sealer) ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn’t break.
the wall as possible, but be
careful that it doesn’t break.
Vinyl tape (Wide) ( )
• Apply after carrying out
• Apply after carrying out
a drainage test.
• To carry out the drainage
test, remove the air
fi lters and pour water
into the heat exchanger.
fi lters and pour water
into the heat exchanger.
Saddle ( )
Installation parts you
should purchase ( )
should purchase ( )
A
Indoor
unit
unit
B
Outdoor
unit
unit
IMPORTANT
Begin the installation job from
the “Indoor Unit” installation.
the “Indoor Unit” installation.
•
This illustration is for
explanation purposes only.
The indoor unit will actually
face a different way.
explanation purposes only.
The indoor unit will actually
face a different way.