CS-MZ20UD3EA - Panasonic Air Conditioner Service Manual (repair manual). Page 13

Read Panasonic CS-MZ20UD3EA Service Manual online

13 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to four separate rooms for CU-4Z68TBE, CU-4Z80TBE. 
o  A single outdoor unit enables air conditioning of up to five separate rooms for CU-5Z90TBE. 
 
CONNECTABLE INDOOR UNIT CU-4Z68TBE 
CU-4Z80TBE 
CU-5Z90TBE 
ROOM 
A B C D A B C D A B C D E 
Wall
 
2.0kW CS-MZ20UD3EA  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-Z25UD3EAW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-Z35UD3EAW  ● 
● 
● – ● 
● 
● 
● 
● 
● 
● 
● 
● 
5.0kW CS-Z50UD3EAW  ● 
● – – ●
– – ●
 
 
● – – 
6.0kW CS-Z60UD3EAW  ● – – – ●
– – ●
 
 
– – – 
Capacity range of connectable units 
From 4.5kW to 11.5kW 
From 4.5kW to 14.7kW 
From 4.5kW to 18.3kW 
Pipe length 
1 room maximum pipe length (m) 
25 
25 
25 
Allowable elevation (m) 
15 
15 
15 
Total allowable pipe length (m) 
60 
70 
80 
Total pipe length for maximum 
chargeless length (m) 
30 45 
45 
Additional gas amount over 
chargeless length (g/m) 
20 20 
20 
Note: “●” : Available 
Remarks for CU-4Z68TBE / CU-4Z80TBE / CU-5Z90TBE 
1. 
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-4Z80TBE. (Total nominal capacity of indoor units is between 
4.5kW to 14.7kW) 
1) Two CS-Z25UD3EAW only. (Total nominal cooling capacity is 5.0kW) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 103
Display