CS-MP9DD4H5, CS-MP14DD4H5, CS-MP18DD4H5, CS-MP18DD3H5, CS-MP24DD3H5, CS-MP24DD2H5, CS-MP18DB4H5, CS-MP24DB4H5 - Panasonic Air Conditioner Service Manual (repair manual). Page 2

Read Panasonic CS-MP9DD4H5 / CS-MP14DD4H5 / CS-MP18DD4H5 / CS-MP18DD3H5 / CS-MP24DD3H5 / CS-MP24DD2H5 / CS-MP18DB4H5 / CS-MP24DB4H5 Service Manual online

2
CU-MP28DBH5/CU-MP50DBH5
1. Features
Flexible Installation, Operation and Control
- Intelligent flexible control consists of multiple control
modes like advanced centralized controller, remote switch
and central controller which used in combination with wired
and wireless remote controllers, realize easy installation,
layout, operation and control.
Highly Efficient Inverter Technique
“MASTE ”
R series uses Panasonic advanced inverter technique,
intelligent and flexible control ability, and realize power and
energy saving; In the meantime, one powerful outdoor unit can
drive multiple indoor units.
Multiple Choice Of Model
- There are 5 different designs like
Hide-away Type (Super-thin),
Hide-away Type (Low Static Pressure),
Hide-away Type (Medium Static Pressure),
Cassette Type,
Wall-mounted Type.
Altogether 11 models make up a wide range of indoor
units which responds to the modern free and changeable
residence space choice.
Hide-away Type(Super-thin Type) Indoor Unit
- Light body with a thickness of 20cm only.
- Flexible installation mode
Hide-away Type(Low Static Pressure)
Indoor Unit
- Flexible and convenient draining mode
- Flexible air return mode
- Light and thin design with thickness of 27cm, allowing
easy installation.
- Extended air duct system.
- Flexible and convenient draining mode
Hide-away Type(Medium Static Pressure)
Indoor Unit
- Light and thin design with thickness of 29cm, allowing
easy installation
- Multiple air outlet vents
-
- Extended air duct system.
Flexible and convenient draining mode
Wall-mounted Type Indoor Unit
- Delicate design
- Easy installation
- Refrigerant distributor
6HP Outdoor Unit
- Quantity of connected indoor units( maximum): 6
- Applicable power supply:220V~50Hz
- Referential applicable area: 81-130m
2
- Long piping: The refrigeration pipe is as long as 90m( main
pipe is 40m) so that the installation position is
naturally out of limits.
- Big height difference: The height difference between the
indoor and outdoor units can reach up to 30m, while the
height difference between indoor units can be 15m at
most.
6HP Outdoor Unit
- Quantity of connected indoor units( maximum): 3
- Applicable power supply:220V~50Hz
- Referential applicable area: 39-64m
2
- Long piping: The refrigeration pipe is as long as 60m
( main pipe is 30m) so that the installation position is
naturally out of limits.
- Big height difference: The height difference between
the indoor and outdoor units can reach up to 15m,
while the height difference between indoor units
can be 10m at most.
Page of 127