Serviceability
     − 
− 
− 
− 
Self diagnosis
     − 
− 
− 
− 
Test Run at both Cooling and Heating rated frequency
    
·
    
Built-in drain pump
     − 
− 
− 
− 
A drain pump is built in.
The pipe can rise to 200 mm above the drain outlet.
2 Features
    
·
    
Product
     − 
− 
− 
− 
A single OUTDOOR unit enables air conditioning of up to four separate rooms
Remarks:
 1. At least two indoor units must be connected.
 2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of outdoor unit. (Shown in the above table)
Example: The below indoor units combination is not possible to connect CU-3E23CBPG. (Total nominal capacity
of indoor unit is between 5.0kW and 10.0kW)
1) Two CS-ME7EB1E only. (Total nominal cooling capacity is 4.4kW)
2) Three CS-ME14EB1E only. (Total nominal cooling capacity is 12.0kW)
     − 
− 
− 
− 
Inverter controlled for High energy efficiency and optimal comfort
     − 
− 
− 
− 
New refrigerant R410A is used for protecting ozone layer
     − 
− 
− 
− 
Lead - free P.C. Board