CS-ME10DD3EG, CS-ME10DTEG, CS-E15DB4EW, CS-ME7DKDG, CS-E9DKDW, CS-E12DKDW, CS-E15DKDW, CS-E18DKDW, CS-E15DD3EW, CS-E18DD3EW, CS-E15DTEW, CS-E18DTEW, CS-E18DB4EW - Panasonic Air Conditioner Service Manual Simplified (repair manual)

cs-me10dd3eg, cs-me10dteg, cs-e15db4ew, cs-me7dkdg, cs-e9dkdw, cs-e12dkdw, cs-e15dkdw, cs-e18dkdw, cs-e15dd3ew, cs-e18dd3ew, cs-e15dtew, cs-e18dtew, cs-e18db4ew service manual simplified
Model
CS-ME10DD3EG CS-ME10DTEG CS-E15DB4EW CS-ME7DKDG CS-E9DKDW CS-E12DKDW CS-E15DKDW CS-E18DKDW CS-E15DD3EW CS-E18DD3EW CS-E15DTEW CS-E18DTEW CS-E18DB4EW
Pages
127
Size
40.7 MB
Type
PDF
Document
Service Manual Simplified
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-me10dd3eg-cs-me10dteg-cs-e15db4ew-cs-me7dkdg-cs.pdf
Date

Read Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Service Manual Simplified online

 1 Features 
3
 2 About Lead Solder (PbF) 
4
 2.1. 
DISTINCTION OF PbF P.C. BOARD 
4
 2.2. 
CAUTION 
4
 3 Functions 
5
 3.1. 
Wall Type 
5
 3.2. 
Duct Type 
8
CS-ME7DKEG CS-ME10DD3EG
CS-ME10DTEG CS-E15DB4EW
CS-ME7DKRG CS-ME7DKDG
CS-E9DKEW CS-E9DKRW
CS-E9DKDW CS-E12DKEW
CS-E12DKRW CS-E12DKDW
CS-E15DKEW CS-E15DKRW
CS-E15DKDW CS-E18DKEW
CS-E18DKRW CS-E18DKDW
CS-E15DD3EW CS-E18DD3EW
CS-E15DTEW CS-E18DTEW
CS-E18DB4EW
 3.3. 
Ceiling Floor Type 
11
 3.4. 
Mini-Cassette Type 
13
 4 Product Specifications 
15
 4.1. 
Wall Type 
15
 4.2. 
Duct Type 
16
 4.3. 
Ceiling Floor Type 
17
 4.4. 
Mini-Cassette Type 
18
Multi Air Conditioner
Please file and use this manual together with the Service Manuals for the following models:
Indoor unit models: CS-ME7CKPG, CS-ME10CKPG, CS-ME12CKPG, CS-ME14CKPG and CS-ME18CKPG;
Outdoor unit models: CU-2E15CBPG, CU-2E18CBPG, CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0209005C2); Indoor unit models: CS-ME7CB1P, CS-ME10CB1P, CS-ME12CB1P, CS-ME14CB1P, CS-
ME10CD3P and CS-ME14CD3P; Outdoor unit models: CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0312001A8)
CONTENTS
 Page 
Page
Order No. RAC0503011C2
 4.5. 
Outdoor units: CU-2E15CBPG / CU-2E18CBPG 
19
 4.6. 
Outdoor units: CU-3E23CBPG / CU-4E27CBPG 
20
 5 Dimensions 
24
 5.1. 
Wall Type 
24
 5.2. 
Duct Type 
26
 5.3. 
Ceiling Floor Type 
28
 5.4. 
Mini-Cassette Type 
29
 6 Refrigeration Cycle Diagram 
30
 6.1. 
CU-2E15CBPG / CU-2E18CBPG 
30
 6.2. 
CU-3E23CBPG / CU-4E27CBPG 
31
 7 Block Diagram 
32
 8 Wiring Diagram 
33
 8.1. 
Wall Type 
33
 8.2. 
Duct Type 
34
 8.3. 
Ceiling Floor Type 
35
 8.4. 
Mini-Cassette Type 
36
 9 Operation Details 
37
 9.1. 
Wall Type 
37
 9.2. 
Duct Type 
54
 9.3. 
Ceiling Floor Type 
60
 9.4. 
Mini-Cassette Type 
74
 10 Self Diagnosis Display 
88
 10.1. Breakdown Self Diagnosis Function (Three Digits
Alphanumeric Code) 
88
 10.2. Error Code 
89
 11 Installation Instructions 
93
 11.1. Wall Type 
93
 11.2. Duct Type 
101
 11.3. Ceiling Floor Type 
110
 11.4. Mini-Cassette Type 
116
 12 Operating Instructions 
125
 13 Installation and Servicing Air Conditioner Using R410A 
139
 13.1. OUTLINE 
139
 13.2. TOOLS FOR INSTALLING/SERVICING REFRIGERANT
PIPING 
140
 13.3. REFRIGERANT PIPING WORK 
144
 13.4. INSTALLATION, TRANSFERRING, SERVICING 
147
 14 Disassembly of Parts 
151
 14.1. Wall Type 
151
 14.2. Duct Type 
153
 14.3. Ceiling Floor Type 
155
 14.4. Mini-Cassette Type 
156
 15 Technical Data 
158
 15.1. Operation Characteristics 
158
 16 Electronic Circuit Diagram 
164
 16.1. Wall Type 
164
 16.2. Duct Type 
171
 16.3. Ceiling Floor Type 
173
 16.4. Mini-Cassette Type 
179
 17 Exploded View and Replacement Parts List 
186
 17.1. Wall Type 
186
 17.2. Duct Type 
192
 17.3. Ceiling Floor Type 
194
 17.4. Mini-Cassette Type 
196
2
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
1 Features
     • 
• 
• 
• 
Product
     − 
− 
− 
− 
A single OUTDOOR unit enable air conditioning of up to two separate rooms for CU-2E15CBPG and CU-2E18CBPG.
     − 
− 
− 
− 
A single OUTDOOR unit enable air conditioning of up to three separate rooms for CU-3E23CBPG.
     − 
− 
− 
− 
A single OUTDOOR unit enable air conditioning of up to four separate rooms for CU-4E27CBPG.
Remarks for CU-2E15CBPG / CU-2E18CBPG:
 1. At least two indoor units must be connected.
 2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (shown in the above table.)
Example: The below indoor units combination is possible to connect CU-2E15CBPG. (Total nominal capacity of indoor
units is between 4.4 kW and 5.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME7DKEG and one CS-E9DKEW. (Total nominal cooling capacity is 5.0 kW.)
Remarks for CU-3E23CBPG / CU-4E27CBPG:
 1. At least two indoor units must be connected.
 2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (shown in the above table.)
Example: The below indoor units combination is possible to connect CU-3E23CBPG. (Total nominal capacity of indoor
units is between 5.0 kW and 10.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME12DKEG. (Total nominal cooling capacity is 9.6 kW.)
3
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
     • 
• 
• 
• 
Serviceability
     − 
− 
− 
− 
Self diagnosis
     − 
− 
− 
− 
Test Run at both Cooling and Heating rated frequency
     • 
• 
• 
• 
Built-in drain pump (Cassette and Duct type)
     − 
− 
− 
− 
A drain pump is built in.
The pipe can rise to 200m above the drain outlet.
2 About Lead Solder (PbF)
2.1. DISTINCTION OF PbF P.C. BOARD
P.C. Boards (manufactured) using lead free solder will have a PbF stamp on the P.C. Board.
2.2. CAUTION
     • 
• 
• 
• 
Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70 °F (30 - 40 °C) higher.
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
     • 
• 
• 
• 
Pb free solder will tend to slash when heated too high (about 1100 °F/ 600°C).
If you must use Pb solder, please completely all of the Pb free solder on the pins or solder area before applying Pb solder. If
this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
4
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
Page of 127
Display

Download Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Service Manual Simplified

Here you can read online and download Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Service Manual Simplified in PDF. CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW service manual simplified will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.