CS-MC95KE, CS-MC125KE, CS-MC76KE, CS-MC126KE, CU-MC145KE, CU-MC185KE, CU-MC205KE, CU-MC245KE, CU-MC196KE - Panasonic Air Conditioner Service Manual (repair manual). Page 97

Read Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual online

220V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
3.55
2.69
1.06
3.32
2.58
1.14
3.09
2.48
1.22
2.81
2.36
1.32
19.0°C
3.58
1.16
19.5°C
3.90
2.82
1.08
3.64
2.71
1.16
3.39
2.61
1.25
3.08
2.48
1.34
22.0°C
4.25
2.92
1.10
3.97
2.81
1.19
3.69
2.71
1.27
3.36
2.59
1.37
230V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.42
1.83
0.71
2.26
1.76
0.76
2.10
1.69
0.81
1.91
1.61
0.88
19.0°C
2.44
0.77
19.5°C
2.66
1.92
0.72
2.48
1.85
0.77
2.31
1.78
0.83
2.10
1.69
0.89
22.0°C
2.90
1.99
0.73
2.71
1.92
0.79
2.52
1.85
0.84
2.29
1.76
0.91
220V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.38
1.80
0.67
2.22
1.73
0.72
2.07
1.66
0.77
1.88
1.58
0.83
19.0°C
2.40
0.73
19.5°C
2.61
1.89
0.68
2.44
1.82
0.73
2.27
1.75
0.78
2.07
1.66
0.85
22.0°C
2.85
1.96
0.69
2.66
1.88
0.75
2.48
1.82
0.80
2.25
1.73
0.86
230V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
4.84
3.67
1.41
4.52
3.52
1.52
4.21
3.38
1.62
3.83
3.21
1.75
19.0°C
4.88
1.54
19.5°C
5.31
3.84
1.44
4.97
3.69
1.55
4.62
3.55
1.65
4.20
3.38
1.78
22.0°C
5.79
3.99
1.46
5.41
3.83
1.57
5.04
3.70
1.68
4.58
3.52
1.82
220V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
4.76
3.61
1.34
4.45
3.46
1.44
4.14
3.33
1.54
3.76
3.16
1.66
19.0°C
4.80
1.46
19.5°C
5.23
3.78
1.36
4.89
3.63
1.47
4.55
3.50
1.57
4.13
3.33
1.69
22.0°C
5.70
3.92
1.39
5.32
3.77
1.49
4.95
3.64
1.60
4.50
3.47
1.72
230V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.38
1.80
0.75
2.22
1.73
0.81
2.07
1.66
0.86
1.88
1.58
0.93
19.0°C
2.40
0.82
19.5°C
2.61
1.89
0.77
2.44
1.82
0.82
2.27
1.75
0.88
2.07
1.66
0.95
22.0°C
2.85
1.96
0.78
2.66
1.88
0.84
2.48
1.82
0.90
2.25
1.73
0.97
220V
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.32
1.76
0.71
2.17
1.69
0.76
2.02
1.62
0.82
1.83
1.54
0.88
19.0°C
2.34
0.78
19.5°C
2.55
1.84
0.72
2.38
1.77
0.78
2.22
1.70
0.83
2.01
1.62
0.90
22.0°C
2.78
1.91
0.74
2.60
1.84
0.79
2.41
1.77
0.85
2.19
1.69
0.91
97
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
Page of 126
Display

Click on the first or last page to see other CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE service manuals if exist.