CS-MC90KH, CU-MC140KH, CS-MC90KH, CU-MC180KH, CS-MC90KH, CU-3MC200KH - Panasonic Air Conditioner Service Manual (repair manual). Page 45

Read Panasonic CS-MC90KH / CU-MC140KH / CS-MC90KH / CU-MC180KH / CS-MC90KH / CU-3MC200KH Service Manual online

– 44 –
ORDER NO. MAC9807010C3
CS-MC90KH
Technical Data
Operation characteristics
[Conditions]: Room temperature: 27/19
°
C
Cooling operation: At High Fan
Piping length: 5 m
At 220V
CS-MC90KH/CU-3MC200KH
1 Unit Operation
2 Units Operation (A + B1 OR B2)
30
Outside Air Temperature (
°
C)
3
4
5
2.2
2.6
: UNIT A
: UNIT B1 OR B2
3.0
2.4
2.8
l
l
Q : Cooling Capacity (kW)
I : Current (A)
T : Outlet Air
Temp. (
°
C)
LP : Gas Side Piping
Pressure (MPa)
35
40
0.4
0.5
0.6
13
14
15
16
LP
T
Q
3 Units Operation
30
Outside Air Temperature (
°
C)
3
4
5
2.4
2.8
: UNIT A
: UNIT B1 AND B2
3.2
2.2
2.6
3.0
3.6
3.4
l
l
Q : Cooling Capacity (kW)
I : Current (A)
T : Outlet Air
Temp. (
°
C)
LP : Gas Side Piping
Pressure (MPa)
35
40
0.4
0.5
0.6
13
14
15
16
LP
T
Q
Q
2 Units Operation (B1 + B2)
30
Outside Air Temperature (
°
C)
4
5
6
3.0
3.4
3.8
3.2
3.6
T
Q
Q : Cooling Capacity (kW)
I : Current (A)
T : Outlet Air
Temp. (
°
C)
LP : Gas Side Piping
Pressure (MPa)
35
40
0.4
0.5
0.6
13
14
15
16
LP
: UNIT B1 AND B2
l
30
Outside Air Temperature (
°
C)
3
4
5
2.2
2.6
: UNIT A
: UNIT B1 OR B2
3.0
2.4
2.8
l
l
Q : Cooling Capacity (kW)
I : Current (A)
T : Outlet Air
Temp. (
°
C)
LP : Gas Side Piping
Pressure (MPa)
35
40
0.4
0.5
0.6
13
14
15
16
LP
T
Q
Untitled-21
6/26/00, 3:43 PM
44
Page of 83
Display