Read Panasonic CS-MC90KH / CU-MC140KH / CS-MC90KH / CU-MC180KH / CS-MC90KH / CU-3MC200KH Service Manual online
– 3 –
ORDER NO. MAC9807010C3
CS-MC90KH
Indoor Unit (CS-MC90KH)
Functions
Auto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates and stops at 4-second
intervals at low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi and Me
speed. Deodorizing control is
available.
available.
– Soft Dry : Fan rotates at SLo and Lo
speed. Deodorizing control is
available.
available.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Auto Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
AUTO
OFF / ON
Operation Test Running / Pump
Down Switch
Down Switch
TEST RUN
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Red)......
Lights up in operation,
blinks in Automatic
Operation Mode judging
blinks in Automatic
Operation Mode judging
•
SLEEP
(Orange).....
Lights up in Sleep
Mode Operation
Mode Operation
•
TIMER
(Orange).....
Lights up in Timer
Setting
Setting
• Used when test running or servicing.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.