CS-HE9NKD, CS-HE12NKD, CU-HE9NKD, CU-HE12NKD - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-HE9NKD / CS-HE12NKD / CU-HE9NKD / CU-HE12NKD Service Manual online

Indoor CS-HE12NKD 
Model 
Outdoor CU-HE12NKD 
Performance Test Condition 
JIS 
Phase, Hz 
Single, 50 
Power Supply 
V 220 
230 
 
Min.  Mid. Max. Min.  Mid. Max. 
kW 
0.80 3.50 4.00 0.80 3.50 4.00 
BTU/h 
2730 11900 13600 2730 11900 13600 
Capacity 
Kcal/h 
690 3010 3440 690 3010 3440 
Running 
Current 
- 4.2 -  - 4.1 - 
Input 
Power 
190  885 1.16k 190  885 1.16k 
Annual 
Consumption  kWh 
- 443 -  - 443 - 
W/W 
4.21 3.95 3.45 4.21 3.95 3.45 
BTU/hW  14.37 13.45 11.72 14.37 13.45 11.72 
EER 
Kcal/hW  3.63 3.40 2.97 3.63 3.40 2.97 
Power 
Factor 
- 96 -  - 94 - 
dB-A 
42 / 28 / 20 
42 / 28 / 20 
Indoor Noise (H / L / QLo) 
Power Level dB 
58 / - / - 
58 / - / - 
dB-A 
48 / - / - 
48 / - / - 
Cooling 
Outdoor Noise (H / L / QLo) 
Power Level dB 
63 / - / - 
63 / - / - 
kW 
0.80 4.40 6.60 0.80 4.40 6.60 
BTU/h 
2730 15000 22500 2730 15000 22500 
Capacity 
Kcal/h 
690 3780 5680 690 3780 5680 
Running 
Current 
- 5.0 -  - 4.9 - 
Input 
Power 
185 1.07k 1.85k 185 1.07k 1.85k 
W/W 
4.32 4.11 3.57 4.32 4.11 3.57 
BTU/hW  14.76 14.02 12.16 14.76 14.02 12.16 
COP 
Kcal/hW  3.73 3.53 3.07 3.73 3.53 3.07 
Power 
Factor 
- 97 -  - 95 - 
dB-A 
42 / 33 / 30 
42 / 33 / 30 
Indoor Noise (H / L / QLo) 
Power Level dB 
58 / - / - 
58 / - / - 
dB-A 
50 / - / - 
50 / - / - 
Heating 
Outdoor Noise (H / L / QLo) 
Power Level dB 
65 / - / - 
65 / - / - 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
4.78 / 1.64k / 2.91 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
3.86 / 1.74k / 2.22 
Max Current (A) / Max Input Power (W) 
8.4 / 1.85k 
Starting Current (A) 
5.0 
Type 
 
Hermetic Motor / Scroll 
Motor Type 
 
Brushless (4 poles) 
Compressor 
Output Power 
750 
 
 
 
 
 
 
 
 
 
 
 
Page of 107