CS-HE9NKD, CS-HE12NKD, CU-HE9NKD, CU-HE12NKD - Panasonic Air Conditioner Service Manual (repair manual). Page 102

Read Panasonic CS-HE9NKD / CS-HE12NKD / CU-HE9NKD / CU-HE12NKD Service Manual online

102 
17.2  Sensible Capacity Chart 
 
š  CU-HE9NKD 
 
Outdoor Temp. (°C) 
230V 
30 35 40 46 
Indoor wet 
bulb temp. 
TC SHC  IP  TC SHC  IP  TC SHC  IP  TC SHC  IP 
17.0°C  2.48 1.88 0.48 2.32 1.80 0.51 2.16 1.73 0.55 1.96 1.65 0.59 
19.0°C 
   
2.50 
 
0.52 
      
19.5°C  2.72 1.97 0.49 2.55 1.89 0.52 2.37 1.82 0.56 2.15 1.73 0.60 
22.0°C  2.97 2.04 0.49 2.77 1.96 0.53 2.58 1.89 0.57 2.35 1.81 0.61 
 
š  CU-HE12NKD 
 
Outdoor Temp. (°C) 
230V 
30 35 40 46 
Indoor wet 
bulb temp. 
TC SHC  IP  TC SHC  IP  TC SHC  IP  TC SHC  IP 
17.0°C  3.47 2.63 0.82 3.24 2.52 0.88 3.02 2.43 0.94 2.74 2.30 1.01 
19.0°C 
   
3.50 
 
0.89 
      
19.5°C  3.81 2.76 0.83 3.56 2.65 0.89 3.31 2.55 0.96 3.01 2.43 1.03 
22.0°C  4.15 2.86 0.85 3.88 2.75 0.91 3.61 2.65 0.97 3.28 2.53 1.05 
 
TC     - Total Cooling Capacity (kW) 
SHC  - Sensible Heat Capacity (kW) 
IP      - Input Power (kW) 
Indoor 27°C/19°C 
Outdoor 35°C/24°C 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 107