Read Panasonic CS-HE9NKD / CS-HE12NKD / CU-HE9NKD / CU-HE12NKD Service Manual online
102
17.2 Sensible Capacity Chart
CU-HE9NKD
Outdoor Temp. (°C)
230V
30 35 40 46
Indoor wet
bulb temp.
bulb temp.
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.48 1.88 0.48 2.32 1.80 0.51 2.16 1.73 0.55 1.96 1.65 0.59
19.0°C
2.50
0.52
19.5°C 2.72 1.97 0.49 2.55 1.89 0.52 2.37 1.82 0.56 2.15 1.73 0.60
22.0°C 2.97 2.04 0.49 2.77 1.96 0.53 2.58 1.89 0.57 2.35 1.81 0.61
CU-HE12NKD
Outdoor Temp. (°C)
230V
30 35 40 46
Indoor wet
bulb temp.
bulb temp.
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.47 2.63 0.82 3.24 2.52 0.88 3.02 2.43 0.94 2.74 2.30 1.01
19.0°C
3.50
0.89
19.5°C 3.81 2.76 0.83 3.56 2.65 0.89 3.31 2.55 0.96 3.01 2.43 1.03
22.0°C 4.15 2.86 0.85 3.88 2.75 0.91 3.61 2.65 0.97 3.28 2.53 1.05
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C
Click on the first or last page to see other CS-HE9NKD / CS-HE12NKD / CU-HE9NKD / CU-HE12NKD service manuals if exist.