CS-HE9MKD, CU-HE9MKD, CS-HE12MKD, CU-HE12MKD - Panasonic Air Conditioner Service Manual (repair manual). Page 102

Read Panasonic CS-HE9MKD / CU-HE9MKD / CS-HE12MKD / CU-HE12MKD Service Manual online

102
17.2. Sensible Capacity Chart
• CU-HE9MKD
• CU-HE12MKD
230V
Outdoor Temp. (
“C)
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
“C
2.48
1.88
0.48
2.32
1.80
0.51
2.16
1.73
0.55
1.96
1.65
0.59
19.0
“C
2.50
0.52
19.5
“C
2.72
1.97
0.49
2.55
1.89
0.52
2.37
1.82
0.56
2.15
1.73
0.60
22.0
“C
2.97
2.04
0.49
2.77
1.96
0.53
2.58
1.89
0.57
2.35
1.81
0.61
230V
Outdoor Temp. (
“C)
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
“C
3.47
2.63
0.82
3.24
2.52
0.88
3.02
2.43
0.94
2.74
2.30
1.01
19.0
“C
3.50
0.89
19.5
“C
3.81
2.76
0.83
3.56
2.65
0.89
3.31
2.55
0.96
3.01
2.43
1.03
22.0
“C
4.15
2.86
0.85
3.88
2.75
0.91
3.61
2.65
0.97
3.28
2.53
1.05
TC
SHC
IP
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27
“C/19“C
Outdoor 35
“C/24“C
Page of 107
Display

Click on the first or last page to see other CS-HE9MKD / CU-HE9MKD / CS-HE12MKD / CU-HE12MKD service manuals if exist.