CS-HE7QKD, CS-HE9QKD, CS-HE12QKD, CS-HE18QKD, CU-HE7QKD, CU-HE9QKD, CU-HE12QKD, CU-HE18QKD - Panasonic Air Conditioner Service Manual (repair manual). Page 126

Read Panasonic CS-HE7QKD / CS-HE9QKD / CS-HE12QKD / CS-HE18QKD / CU-HE7QKD / CU-HE9QKD / CU-HE12QKD / CU-HE18QKD Service Manual online

126 
18. Service 
Data 
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced 
heating mode. 
18.1  Cool Mode Outdoor Air Temperature Characteristic 
Condition 
Indoor room temperature: 27°C Dry Bulb/19°C Wet Bulb 
Unit setting: Standard piping length, forced cooling at 16°C, Hi fan 
Compressor frequency: Rated for cooling operation 
Piping length: 5m 
- Voltage: 
220V/230V 
18.1.1 CS/CU-HE7QKD 
 
12.00
13.00
14.00
15.00
16.00
17.00
18.00
19.00
20.00
21.00
22.00
12
16
20
24
28
32
36
40
44
48
Outlet Air (°
C)
Outdoor Air Temperature (°C)
0.80
0.90
1.00
1.10
1.20
1.30
1.40
12
16
20
24
28
32
36
40
44
48
Lo
w Press
u
re (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
1.00
1.50
2.00
2.50
3.00
3.50
12
16
20
24
28
32
36
40
44
48
230V
220V
 
 
 
 
Page of 127
Display