4.1.3.
CS-F28DD2E5 CU-YL28HBE5
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50 Hz)
ITEM / MODEL
Indoor Unit
Outdoor Unit
Main Body
CS-F28DD2E5
CU-YL28HBE5
Cooling Capacity
kW
7.1 (2.1 ~ 7.7)
BTU/h
24,200 (7,200 ~ 26,300)
Heating Capacity
kW
8.0 (2.2 ~ 8.3)
BTU/h
27,300 (7,500 ~ 28,300)
Refrigerant Charge-less
m
30
Standard Air Volume for High,
m
3
/min
Hi 22
Hi 58
Medium and Low Speed
cfm
Hi 777
2048
External Static Pressure
Pa
Hi 69
—
mmAq
Hi 7.0
Outside Dimension (H x W x D)
mm
290
× 1000 + 100 × 500
795
× 875 × 320
inch
11-13/32
× 39-3/8 + 3-15/16 × 19-21/32
31-5/16
× 34-7/16 × 12-19/32
Net Weight
kg (lbs)
35 (78)
65 (143)
Piping
Connection
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 15.88 (5/8) Flared Type
Liquid
mm (inch)
O.D Ø 9.53 (3/8) Flared Type
Drain
mm
O.D Ø 32
I.D Ø 20
× 1
Compressor
Type, Number of Set
—
Hermetic - 2P (Rotary), 1
Starting Method
—
DC - INV control
Motor
Type
—
4-pole single phase brushless motor
Rated Output
kW
—
2.0
Fan
Type, Number of Set
Sirocco Fan, 2
Mix flow fan - 1
Motor
Type
4-pole single phase induction motor
6-pole single phase induction motor
Rated Output
kW
0.135
0.07
Air-heat Exchanger (Row x Stage x FPI)
Louvre-fin type (3
× 12 × 15)
Corrugate-fin type (2
× 36 × 17)
Refrigerant Control
—
Exp. Valve
Refrigerant Oil (Charged)
cm
3
—
FV50S (800)
Refrigerant (Charged) R410A
kg (oz)
—
2.05 (72.3)
Running
Adjustment
Adjustment
Control Switch
Wired Remote Control
—
Room Temperature
Thermostat
—
Safety Devices
Temperature, current and pressure protection control for compressor,
Internal thermostat for FM, High pressure switch,
Current trans, Crankcase heater
Noise Level
dB (A)
Cooling : Hi 45 Lo 41
Heating : Hi 43 Lo 39
Heating : Hi 43 Lo 39
Cooling 50, Heating 52
Power level dB
Cooling : Hi 61 Lo 57
Heating : Hi 59 Lo 55
Heating : Hi 59 Lo 55
Cooling 68, Heating 69
Moisture Removal
L/h (Pt/h)
4.2 (8.8)
EER
W/W
2.81 (3.23 ~ 2.96)
COP
W/W
2.81 (3.67 ~ 2.59)
ITEM / MODEL
Condition by ISO5151
Volts
V
220
230
240
Phase
Single
Single
Single
Power Consumption
kW
Cool
2.53 (0.65 ~ 2.60)
Heat
2.85 (0.6 ~ 3.2)
Running Current
A
Cool
11.8
11.5
11.3
Heat
13.2
12.8
12.4
Starting Current
A
12.5
12.2
12.0
Power Factor
%
Cool
97
96
93
Heat
98
97
96
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Panasonic
Power source
AC, 1~220V, 230V, 240V 50Hz