13.4.2. Heating performance
Model name
Max heating capacity
Max capacity (kw)
Max power consumption (kw)
CS-F24DD2E5 / CU-L24DBE5
7.5
3.15
CS-F28DD2E5 / CU-L28DBE5
8.5
3.25
CS-F34DD2E5 / CU-L34DBE5
13.5
4.3
CS-F43DD2E5 / CU-L43DBE5
15.5
5.1
CS-F50DD2E5 / CU-L50DBE8
18
6.1
 1. Heating capacity when the unit is frosted over or while being defrosted will vary depending on outdoor temperature and the
frosting.
 2. Heating capacity must be compensated because it does not take into account the capacity drop incurred when the unit is
frosted over and while it is being defrosted.
 3. Therefore, to obtain the integral heating capacity in consideration overfrosting and defrost operations.
 4. Heating capacity must be multiplied by the compensation coefficient below.