Read Panasonic CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD Service Manual online
10
Model
Indoor CS-E12RKDW
CS-E15RKDW
Outdoor
CU-E12RKD
CU-E15RKD
Drain Hose
Inner Diameter
mm
16.7
16.7
Length mm
650
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 21
2 x 15 x 21
Size (W x H x L)
mm
610 x 315 x 25.4
610 x 315 x 25.4
Outdoor
Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Corrugated Fin
Row x Stage x FPI
2 x 24 x 17
2 x 24 x 17
Size (W x H x L)
mm
36.4 x 504 x 713:684
36.4 x 504 x 713:684
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Outdoor Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Nil
Thermostat
Electronic Contol
Electronic Contol
Protection Device
Electronic Contol
Electronic Contol
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum
°C
32 23 32 23
Minimum
°C
16 11 16 11
Heating
Maximum
°C
30 - 30 -
Minimum
°C
16 - 16 -
Outdoor
Operation
Range
Cooling
Maximum
°C
43 26 43 26
Minimum
°C
10 - 10 -
Heating
Maximum
°C
24 18 24 18
Minimum
°C
-10 - -10 -
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.