CS-E7RKDW, CS-E9RKDW, CS-E12RKDW, CS-E15RKDW, CS-E18RKDW, CS-E24RKDW, CS-E28RKDS, CU-E7RKD, CU-E9RKD, CU-E12RKD, CU-E15RKD, CU-E18RKD, CU-E24RKD, CU-E28RKD - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD Service Manual online

Model 
Indoor CS-E12RKDW 
CS-E15RKDW 
Outdoor CU-E12RKD 
CU-E15RKD 
Performance Test Condition 
JIS 
JIS 
Power Supply 
Phase, Hz 
Single, 50 
Single, 50 
V 220 
230 
220 
230 
 
Min.  Mid. Max.
Min.  Mid. Max.
Min.  Mid. Max. Min.  Mid. Max.
Cooling 
Capacity 
kW 
0.85 3.50 4.00 0.85 3.50 4.00 0.85 4.20 5.00 0.85 4.20 5.00 
BTU/h 
2900 11900 13600 2900 11900 13600 2900 14300 17100 2900 14300 17100
Kcal/h 
730 3010 3440
730 3010 3440
730 3610 4300 730 3610 4300
Running 
Current 
- 4.3 -  - 4.1 -  - 5.9 -  - 5.7 - 
Input 
Power 
250  905 1.18k
250  905 1.18k
260 1.26k 1.57k 260 1.26k 1.57k
Annual 
Consumption 
kWh 
- 453 -  - 453 -  - 630 -  - 630 - 
EER 
W/W 
3.40 3.87 3.39 3.40 3.87 3.39 3.27 3.33 3.18 3.27 3.33 3.18 
BTU/hW 
11.60 13.15 11.53 11.60 13.15 11.53 11.15 11.35 10.89 11.15 11.35 10.89
Kcal/hW 
2.92 3.33 2.92 2.92 3.33 2.92 2.81 2.87 2.74 2.81 2.87 2.74 
Power 
Factor 
- 96 -  - 96 -  - 97 -  - 96 - 
Indoor Noise (H / L / QLo) 
dB-A 
42 / 28 / 21 
42 / 28 / 21 
43 / 31 / 25 
43 / 31 / 25 
Power Level dB 
58 / - 
58 / - 
59 / - 
59 / - 
Outdoor Noise (H / L) 
dB-A 
48 / - 
48 / - 
49 / - 
49 / - 
Power Level dB 
63 / - 
63 / - 
64 / - 
64 / - 
Heating
 
Capacity 
kW 
0.85 4.40 6.70 0.85 4.40 6.70 0.85 5.30 6.80 0.85 5.30 6.80 
BTU/h 
2900 15000 22800 2900 15000 22800 2900 18100 23200 2900 18100 23200
Kcal/h 
730 3780 5760
730 3780 5760
730 4560 5850 730 4560 5850
Running 
Current 
- 5.3 -  - 5.1 -  - 6.8 -  - 6.6 - 
Input 
Power 
245 1.09k 1.93k
245 1.09k 1.93k
255 1.44k 1.94k 255 1.44k 1.94k
COP 
W/W 
3.47 4.04 3.47 3.47 4.04 3.47 3.33 3.68 3.51 3.33 3.68 3.51 
BTU/hW 
11.84 13.76 11.81 11.84 13.76 11.81 11.37 12.57 11.96 11.37 12.57 11.96
Kcal/hW 
2.98 3.47 2.98 2.98 3.47 2.98 2.86 3.17 3.02 2.86 3.17 3.02 
Power 
Factor 
- 93 -  - 93 -  - 96 -  - 95 - 
Indoor Noise (H / L / QLo) 
dB-A 
42 / 33 / 30 
42 / 33 / 30 
43 / 35 / 32 
43 / 35 / 32 
Power Level dB 
58 / - 
58 / - 
59 / - 
59 / - 
Outdoor Noise (H / L) 
dB-A 
50 / - 
50 / - 
51 / - 
51 / - 
Power Level dB 
65 / - 
65 / - 
66 / - 
66 / - 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
4.86 / 1.71k / 2.84 
4.92 / 1.72k / 2.86 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
3.75 / 1.68k / 2.23 
3.94 / 1.83k / 2.15 
Max Current (A) / Max Input Power (W) 
8.9 / 1.93k 
9.0 / 1.94k 
Starting Current (A) 
5.3 
6.8 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (6 poles) 
Brushless (6 poles) 
Output Power 
700 
700 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD service manuals if exist.