Model 
Indoor CS-E7RKDW 
CS-E9RKDW 
Outdoor 
CU-E7RKD 
CU-E9RKD 
Drain Hose 
Inner Diameter 
mm  
16.7 
16.7 
Length mm 
650 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
2 x 15 x 17 
2 x 15 x 21 
Size (W x H x L) 
mm 
610 x 315 x 25.4 
610 x 315 x 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Blue Coat) 
Aluminium (Blue Coat) 
Fin Type 
 
Corrugated Fin 
Corrugated Fin 
Row x Stage x FPI 
 
1 x 20 x 19 
2 x 24 x 17 
Size (W x H x L) 
mm 
22 x 508 x 708 
36.4 x 504 x 713:684 
Air Filter 
Material  
Polypropelene 
Polypropelene 
Type  
One-touch 
One-touch 
Power Supply 
 
Outdoor Power Supply 
Outdoor Power Supply 
Power Supply Cord 
Nil 
Nil 
Thermostat 
 
Electronic Contol 
Electronic Contol 
Protection Device 
 
Electronic Contol 
Electronic Contol 
 
Dry Bulb 
Wet Bulb 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum 
°C 
32 23 32 23 
Minimum 
°C 
16 11 16 11 
Heating 
Maximum 
°C 
30 - 30 - 
Minimum 
°C 
16 - 16 - 
Outdoor 
Operation 
Range 
Cooling 
Maximum 
°C 
43 26 43 26 
Minimum 
°C 
10 - 10 - 
Heating 
Maximum 
°C 
24 18 24 18 
Minimum 
°C 
-10 - -10 - 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C 
5. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 