CS-E7RKDW, CS-E9RKDW, CS-E12RKDW, CS-E15RKDW, CS-E18RKDW, CS-E24RKDW, CS-E28RKDS, CU-E7RKD, CU-E9RKD, CU-E12RKD, CU-E15RKD, CU-E18RKD, CU-E24RKD, CU-E28RKD - Panasonic Air Conditioner Service Manual (repair manual). Page 3

Read Panasonic CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD Service Manual online

CAUTION
 
WARNING
 
WARNING
1. Safety Precautions 
  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
 
This indication shows the possibility of causing death or serious injury. 
 
This indication shows the possibility of causing injury or damage to properties. 
 
  The items to be followed are classified by the symbols: 
 
 
  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
 
 
1.  
Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit on veranda of a high rise building, child may 
climb up to outdoor unit and cross over the handrail causing an accident. 
 
2. 
Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with 
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 
 
3.  Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen. 
4.  Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.   
 
5.  Do not sit or step on the unit, you may fall down accidentally.   
 
6.  Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. 
7. 
When installing or relocating air conditioner, do not let any substance other than the specified refrigerant, eg. air etc mix into 
refrigeration cycle (piping). Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
 
8.  Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc. 
9. 
• For R410A model, use piping, flare nut and tools which is specified for R410A refrigerant. Using of existing (R22) piping, flare nut and tools
  may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and injury. 
• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm. 
• It is desirable that the amount of residual oil less than 40 mg/10 m. 
10. 
Engage authorized dealer or specialist for installation. If installation done by the user is incorrect, it will cause water leakage, electrical shock 
or fire. 
11.  Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
12. 
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical 
shock. 
13. 
Install at a strong and firm location which is able to withstand weight of the set. If the strength is not enough or installation is not properly 
done, the set will drop and cause injury. 
14. 
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single 
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
15. 
Do not use joint cable for indoor / outdoor connection cable. Use the specified indoor/outdoor connection cable, refer to installation 
instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor/outdoor connection. Clamp the cable so that no 
external force will have impact on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the connection. 
16. 
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
fire or electrical shock. 
17. 
This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). 
Otherwise, it may cause electrical shock and fire in case of equipment breakdown or insulation breakdown. 
18. 
During installation, install the refrigerant piping properly before running the compressor. Operation of compressor without fixing refrigeration 
piping and valves at opened position will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
19. 
During pump down operation, stop the compressor before removing the refrigeration piping. Removal of refrigeration piping while 
compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in 
explosion, injury etc. 
 
This symbol denotes item that is PROHIBITED from doing. 
Page of 127
Display

Click on the first or last page to see other CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD service manuals if exist.