CS-E7RKDW, CS-E9RKDW, CS-E12RKDW, CS-E15RKDW, CS-E18RKDW, CS-E24RKDW, CS-E28RKDS, CU-E7RKD, CU-E9RKD, CU-E12RKD, CU-E15RKD, CU-E18RKD, CU-E24RKD, CU-E28RKD - Panasonic Air Conditioner Service Manual (repair manual). Page 16

Read Panasonic CS-E7RKDW / CS-E9RKDW / CS-E12RKDW / CS-E15RKDW / CS-E18RKDW / CS-E24RKDW / CS-E28RKDS / CU-E7RKD / CU-E9RKD / CU-E12RKD / CU-E15RKD / CU-E18RKD / CU-E24RKD / CU-E28RKD Service Manual online

16 
Model 
Indoor CS-E28RKDS 
Outdoor CU-E28RKD 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 15.88 (5/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 30 (98.4) 
I/D & O/D Height different 
m (ft) 
20 (65.6) 
Additional Gas Amount 
g/m (oz/ft) 
30 (0.3) 
Length for Additional Gas 
m (ft) 
10 (32.8) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
2 × 15 × 21  
Size (W x H x L) 
mm 
810 × 315 × 25.4 
Outdoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Blue Coat) 
Fin Type 
 
Corrugated Fin 
Row x Stage x FPI 
 
2 × 30 × 19  
Size (W x H x L) 
mm 
38.1 × 762 × 895.8 
                     865.8 
Air Filter 
Material  
Polypropelene 
Type  
One-Touch 
Power Supply 
 
Outdoor Power Supply 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
DRY BULB 
WET BULB 
Indoor Operation Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
 
Minimum °C 
16 
 
Outdoor Operation Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
10 
 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-10 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb  
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 