CS-E24NKDS, CS-E28NKDS, CU-E24NKD, CU-E28NKD - Panasonic Air Conditioner Service Manual (repair manual). Page 101

Read Panasonic CS-E24NKDS / CS-E28NKDS / CU-E24NKD / CU-E28NKD Service Manual online

101 
17.2  Sensible Capacity Chart 
  CS-E24NKDS  CU-E24NKD 
 
 
Outdoor Temp. (ºC) 
30 35 40 46 
Indoor wet 
bulb temp. 
TC SHC  IP  TC SHC
IP  TC SHC
IP  TC SHC
IP 
17.0ºC  6.75 5.11 1.94 6.30 4.90 2.09 5.86 4.71 2.23 5.33 4.48 2.41 
19.0ºC 
         
 
         
 
         
 6.80 
         
2.12 
         
         
         
 
         
 
         
         
19.5ºC  7.41 5.35 1.98 6.92 5.14 2.13 6.44 4.95 2.28 5.85 4.71 2.45 
12.0ºC  8.07 5.55 2.01 7.54 5.34 2.17 7.02 5.15 2.32 6.38 4.91 2.50 
 
  CS-E28NKDS CU-E28NKD 
 
 
 
Outdoor Temp. (ºC) 
30 35 40 46 
Indoor wet 
bulb temp. 
TC SHC  IP  TC SHC
IP  TC SHC
IP  TC SHC
IP 
17.0ºC  7.59 5.75 2.33 7.09 5.52 2.50 6.59 5.30 2.68 6.00 5.04 2.89 
19.0ºC 
         
 
         
 
         
 7.65 
         
2.54 
         
         
         
 
         
 
         
         
19.5ºC  8.33 6.02 2.37 7.79 5.79 2.55 7.24 5.57 2.73 6.59 5.30 2.94 
12.0ºC  9.08 6.25 2.41 8.48 6.01 2.60 7.89 5.79 2.78 7.18 5.53 2.99 
 
 
TC – Total Cooling Capacity (kW) 
SHC – Sensible Heat Capacity (kW) 
IP – Input Power (kW) 
Indoor 27ºC/19ºC 
Outdoor 35ºC/24ºC 
 
 